3.6.1 Attic, Insulation & Ventilation: Electrical Wiring In Attic – Loose Wire End/Splice (Attic)

A loose wire end and/or splice was located. A qualified contractor should evaluate and repair or replace as necessary.

 

3.6.2 Attic, Insulation & Ventilation: Electrical Wiring In Attic – Light switch- Missing Cover Plate (attic)

The light switch was missing a cover plate in the attic area. A qualified contractor should evaluate and repair or replace as necessary.

 

4.2.1 Exterior: Wall-Covering, Flashing & Trim – Loose/damaged- Trim/molding (Back right side)

The exterior wall-covering trim/molding was damaged and loose at the back right side of the home. A qualified contractor should evaluate and repair or replace as necessary.

 

4.2.2 Exterior: Wall-Covering, Flashing & Trim – Missing – Paint (Rear and left side of the home)

The siding and/or trim was missing paint in areas. A qualified contractor should evaluate and repair or replace as necessary.

 

4.4.1 Exterior: Exterior Doors – Missing siding/trim (main entrance)

The main entrance door was missing siding/trim in areas. A qualified contractor should evaluate and repair or replace as necessary.

 

4.6.1 Exterior: Electrical Outlets – outlet/Missing block out (upper rear of the home)

The outlet at the upper rear portion of the home was missing a block out. A qualified contractor should evaluate and repair or replace as necessary.

 

4.7.1 Exterior: Windows – Missing window trim (exterior)

Several windows were missing trim in areas on the exterior. A qualified contractor should evaluate and repair or replace as necessary.

 

4.8.1 Exterior: Window Wells – Window Wells No Ladder (exterior)

Window well(s) lacked an egress ladder. Window wells more that 44″ below grade should have a permanent ladder installed. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 

4.9.1 Exterior: Walkways & Driveways – Signs of Repairs (front porch)

Signs of repairs were present on the front porch. A qualified contractor should evaluate and repair or replace as necessary.

 

4.13.1 Exterior: Sump Pump Discharge Pipe – Missing- Discharge Pipe-extension (front left side)

The sump pump discharge pipe was missing a proper extension and doesn’t properly route drainage away from the foundation. Erosion can continue or become worse if not corrected possibly leading to water intrusion. This condition may cause problems by introducing excessive amounts of moisture to the soil near the foundation. A qualified contractor should evaluate and install a proper extension, to properly route drainage away from the foundation, usually at least 6 feet. A qualified contractor should evaluate and repair or replace as necessary.

 

4.16.1 Exterior: Exterior Vents – exhaust vent-Missing block out (back right side )

The water heater exhaust vent was missing a block out at the back right side of the home. A qualified contractor should evaluate and repair or replace as necessary.

 

5.6.1 Attached Garage: Door Opener – Wall Button-not working (garage)

The push button opener on the wall was not operating properly at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

 

6.2.1 Interior, Doors, Windows: Ceilings & Walls – Damaged walls- Multiple areas (interior)

The ceiling and/or walls showed various signs of minor defects at numerous locations including all or some of the following: cosmetic damage, cracks, holes, previous repairs, and/or improper repairs. A representative number of pictures were taken to provide an example. Should any of these issues appear excessive we recommend a qualified contractor should evaluate and repair or replace items as necessary.

 

6.2.2 Interior, Doors, Windows: Ceilings & Walls – Nail Pops-Ceilings (Front guest bedroom)

There were “nail pops” visible in the interior window in the front guest bedroom. A qualified contractor should evaluate and repair or replace as necessary.

 

6.5.1 Interior, Doors, Windows: Windows – Window-loose/not sealed (living room)

The window was loose and not properly sealed in the living room. A qualified contractor should evaluate and repair or replace as necessary. 

 

7.10.1 Bathroom: Tub, Shower Area – Caulk – Wall Tiles (master bathroom)

One or more tiles in the shower area had insufficient or deteriorated caulking in the master bathroom. The window was loose and not properly sealed in the living room. A qualified contractor should evaluate and repair or replace as necessary. 

 

8.8.1 Bathroom 2: Plumbing Fixtures – Leak – Shower Head (upstairs hall bathroom)

There was a leak at the shower head connection at the time of inspection in the upstairs hall bathroom. A qualified contractor should evaluate and repair or replace as necessary. 

 

9.14.1 Bathroom 3: Window – Window loose-not sealed (main level hall bathroom)

The window was loose and not properly sealed in the main level hall bathroom. A qualified contractor should evaluate and repair or replace as necessary.

 

10.11.1 Kitchen: Range Hood – Vents In To Cabinet (kitchen)

The microwave vent hood vents in to the cabinet space between the top of the microwave and the cabinet above it. A qualified contractor should evaluate and repair or replace as necessary. 

 

12.12.1 Laundry: Windows – Window loose- not sealed (laundry room)

The window was loose and not properly sealed in the laundry area. A qualified contractor should evaluate and repair or replace as necessary.

 

13.7.1 Plumbing: Sump Pit – sump pump lid/ damaged/Not Sealed (basement)

The sub pump lid was cracked and was not sealed at the time of the inspection. The inspector recommends that it be sealed to prevent radon gas from entering the occupied area. A qualified contractor should evaluate and repair or replace as necessary. 

 

15.12.1 Water Heating Equipment: Water Temperature – Water Temperature Low (water heater)

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace as necessary.

 

16.6.1 Heating: Cabinet – Corroded, Rusted, dirty (furnace)

The heating system cabinet was corroded, rusted or dirty/damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.

 

16.6.2 Heating: Cabinet – cabinet door-missing latch (furnace)

The cabinet panel covers was missing a latch at the time of inspection. This may allow the panel to fall off easily, or add difficulty when removing for service. A qualified contractor should evaluate and repair or replace as necessary. 

 

16.6.3 Heating: Cabinet – Refrigerant line not sealed (furnace)

The refrigerant line was not properly secured/sealed at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary. 

 

16.8.1 Heating: Ductwork – ducts-Dirty (furnace)

The HVAC supply and return ducts were dirty at the time of the inspection and in need of cleaning. Recommend having all the HVAC supply and return ducts cleaned by a qualified contractor. 

 

17.3.1 Cooling: AC Compressor – Unit is Not Level (AC)

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 

18.2.1 Structural Basement: Basement Floor Structure – Cracked – Common (structural basement)

The concrete floor in the basement was cracked as well as showed signs of repair in areas. These cracks appear to be common cracks indicating regular settlement or heaving, but not necessarily structural problems. Recommend a qualified contractor to evaluate to make further recommendations and repair as necessary.