2.2.1 – Roof Covering
Roof Covering 1
Roof Covering 2
BULGING/BUBBLING

The roof covering was bulged or bubbled in some areas, which may make it more susceptible to damage. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.2.2 – Roof Covering
Roof Covering 3
Roof Covering 4
Roof Covering 5
DEBRIS

The roof was covered with debris in areas. This condition could trap moisture and conceal damage. Latent defects may exist. A qualified contractor should evaluate, then repair or replace as advised.

 3 – Exterior
3.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
MISSING – PAINT

The siding and/or trim in areas were missing paint.

Recommend a qualified contractor should evaluate and repair or replace as needed.

3.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 2
Wall-Covering, Flashing & Trim 3
Wall-Covering, Flashing & Trim 4
PEELING PAINT

Peeling paint was present in areas.

Recommend a qualified contractor should evaluate and repair or replace as needed.

3.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 5
SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

3.7.1 – Electrical Fixtures
LOOSE ON WALL
BACK

An exterior light fixture was loosely mounted to the wall and should be secured tighter. A qualified contractor should evaluate and repair or replace as necessary.

3.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
DENSE VEGETATION

Dense vegetation was present around the house in areas.  This condition limited and restricted my visual inspection.  Dense vegetation and landscaping up against or near the house foundation and exterior walls may be prone to water penetration and insect infestation. Trimming, pruning, and some landscaping are recommended by a qualified contractor

3.12.2 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 2
Vegetation, Grading & Drainage 3
NEGATIVE GRADING

The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation.  Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving, or settling, depending on soil composition, moisture content, and other conditions. The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters, and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.

3.12.3 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 4
TREE BRANCHES OVER PROPERTY

Large trees near the house have branches that overhang the property. Falling branches due to conditions such as wood decay, high winds, or heavy snow loads may cause injury, death, or damage. Significant weakening of large branches by conditions such as core decay may not be visible by persons without special training. Consider having these trees evaluated by a qualified arborist. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

3.20.1 – Railings & Handrails
Railings & Handrails 1
HORIZONTAL RAILINGS

The guard/handrail had horizontal railings. This creates a climbing risk and a fall or injury could occur if not corrected. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

 5 – Detached Garage
5.2.1 – Roof Covering
Detached Garage Roof Covering 1
MOUNTING PENETRATIONS SEALANT

An object mounted to the roof had fasteners that were improperly installed and were not sealed. This condition may allow moisture to enter the roof and attic systems if not corrected.

A qualified contractor should evaluate and repair or replace as necessary.

5.2.2 – Roof Covering
Roof Covering 1
FLASHING DEFECT

A defect was noted in the flashing at the detached garage roof covering at the time of inspection. Recommend a qualified contractor evaluate further and repair or replace as needed

5.3.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
DAMAGED WALL-COVERING MATERIAL

The exterior wall-covering material was damaged.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.3.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 2
CRACKING – MINOR

The siding showed cracking in one or more places. Recommend monitoring, and if the problem exacerbates, a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.3.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 3
Wall-Covering, Flashing & Trim 4
PEELING PAINT

The inspector observed peeling paint in areas. A qualified contractor should evaluate and repair as necessary.

5.4.1 – Gutters & Downspouts
Gutters & Downspouts 1
DAMAGED – GUTTER

The gutters were damaged in one or more areas.

A qualified contractor should evaluate and repair or replace as needed.

5.5.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
Vegetation, Grading & Drainage 2
DENSE VEGETATION

I observed dense vegetation around the house in areas.  This condition limited and restricted my visual inspection.  Dense vegetation and landscaping up against or near the house foundation and exterior walls may be prone to water penetration and insect infestation. Trimming, pruning, and some landscaping are recommended.

5.5.2 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 3
NEGATIVE GRADING

The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation.  Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving, or settling, depending on soil composition, moisture content, and other conditions. The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters, and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.

5.10.1 – Door Opener
Door Opener 1
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

5.13.1 – Stairs & Railings
Stairs & Railings 1
MISSING – HANDRAIL

I observed a missing handrail at the exterior steps.

There is more than one step here, and I recommend installing a handrail for safety.

 6 – Interior, Doors, Windows
6.3.1 – Floors
Floors 1
HUMP

The floor had a noticeable hump or rise.  A qualified contractor should evaluate and repair or replace as necessary.

6.3.2 – Floors
Floors 2
Floors3
WEAR AND TEAR

The floors showed signs of minor damage and wear, particularly in high-traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

6.4.1 – Doors
Doors 1
Doors 2
Doors 3
MISSING – DOORSTOP

The door had a damaged or missing doorstop.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.1 – Windows

Windows 1

MISSING LADDER

The egress window in the basement was missing an escape ladder.

6.6.1 – Electrical Outlets
LOOSE – OUTLET
FRONT

An electrical outlet was loose in the wall. A qualified contractor should evaluate and repair or replace as necessary.

6.7.1 – Electrical Fixtures & Switches
FLICKERING LIGHT
FRONT BEDROOM

The light fixture flickered possibly indicating a loose connection at the switch or fixture.  A qualified contractor should evaluate and repair or replace as necessary.

6.8.1 – Stairways & Railings
Stairways & Railings 1
HORIZONTAL RAILINGS

At the interior stairs, the handrail hand horizontal railings.  This creates a climbing risk for children.  A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

6.8.2 – Stairways & Railings
Stairways & Railings 2
STAIR SQUEAKS

The stair floor squeaks when stepped on.  A qualified contractor should evaluate and repair or replace as necessary.

6.9.1 – Smoke & CO Detectors
CO DETECTOR MISSING
1ST FLOOR

Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends the installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009, which requires Carbon Monoxide detectors to be installed in most properties that have a fuel-burning heater or appliance, a fireplace, or an attached garage.

There are no carbon monoxide detectors on the lower or upper levels.

 7 – Kitchen
7.11.1 – Water Supply Shutoff Valves
Water Supply Shutoff Valves 1
SADDLE VALVE

A saddle valve was present in the plumbing at the time of inspection. They are prone to leak over time as the rubber seal will eventually deteriorate and they clog up as calcium deposits build up at the small opening. Recommend a qualified contractor evaluate and replace it with a permanent valve as needed.

7.14.1 – Range/Oven/Cooktop
Range/Oven/Cooktop 1
DIRTY, EXCESS GREASE

The oven had excess grease or was dirty at the time of inspection. Excess grease may be a fire hazard. Recommend a qualified contractor to evaluate and clean as needed.

 8 – Laundry
8.4.1 – Exhaust Fan
Exhaust Fan 1
FAN NEEDED

There was no ventilation (exhaust fan or openable window) In the laundry area. Normally an exhaust fan or an openable window is needed for proper ventilation.  A qualified contractor should evaluate and repair or replace as necessary.

 9 – Bathroom
9.2.1 – Doors
Bathroom doors 1
 Bathroom doors 2

Bathroom doors 3

MISSING – DOORSTOP

The door had a damaged or missing doorstop.  A qualified contractor should evaluate and repair or replace as necessary.

9.2.2 – Doors
RUBS FRAME
PRIMARY BATHROOM

An interior door rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly.

A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.8.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
NOT WORKING – BULB
UPSTAIRS BATHROOM

One or more bulbs were not working in the bathroom at the time of inspection.

Recommend a qualified contractor to evaluate and repair or replace as needed.

10.14.1 – Tub, Shower Area

Tub, Shower Area 1

CAULK – NEEDS TOUCH-UPS

Some caulking in the tub shower area was loose, old, or poorly done. Recommend a qualified contractor evaluate and re-caulk as needed.

 11 – Plumbing
11.4.1 – Water Pressure
 Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure is measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances are likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

 13 – Water Heating Equipment
13.8.1 – Temperature & Pressure Relief Valve
Temperature & Pressure Relief Valve 1
IMPROPER MATERIAL

An improper material was used for the TPR pipe. The pipe should be a heat-rated material. A qualified contractor should evaluate and repair or replace as necessary.

 14 – Heating
14.6.1 – Cabinet
Cabinet 1
CORRODED, RUSTED

The heating system cabinet was corroded, rusted, or damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.

14.7.1 – Condensate
Condensate 1
SIGNS OF LEAKING

The condensation drain components for the HVAC system were leaking or showing signs of the previous leaking. A qualified contractor should evaluate and repair or replace as necessary.

 15 – Cooling
15.7.1 – Evaporator Coils
Evaporator Coils 1
GAP IN REFRIGERANT LINES

There was a gap where the refrigerant lines enter the plenum. Recommend a qualified contractor evaluate and seal as needed.