2 – Roof
2.4.1 – Flashing
Flashing 1
VALLEY FLASHING DEBRIS BUILD-UP

Valley flashing/shingles used to protect areas of the roof from moisture intrusion appears to be a collection area for debris, which can lead to damage to the roof covering areas. A qualified roofing contractor should evaluate and repair as necessary.

2.8.1 – Roof Drainage Systems
Roof Drainage Systems 1
CORROSION – MODERATE

Gutters had moderate general corrosion visible. Corrosion is generally a sign of poor sloping or drainage, and continued corrosion will eventually result in leaking gutters.

This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

2.8.2 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 2
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration, or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 3 – Attic, Insulation, and Ventilation
3.1.1 – Attic Access
Attic Access 1
HATCH NOT INSULATED

The attic access hatch was not properly insulated. A qualified contractor should evaluate and repair or replace as necessary.

3.4.1 – Insulation in Attic
Insulation in Attic 1
COMPRESSED – INSULATION

The insulation had been walked on or had stored items compressing it, which reduces the R-value.

Recommend a qualified contractor to evaluate and repair or replace as needed.

3.4.2 – Insulation in Attic
Insulation in Attic 2
NOT UNIFORM

The insulation is not uniform: thicker in areas, thinner in areas, or possibly missing in some areas.

Recommend a qualified contractor to evaluate and repair or replace as needed.

3.4.3 – Insulation in Attic
Insulation in Attic 3
TOO THIN

The insulation is thinner than current thermal resistance (R-value) standards.

Recommend a qualified contractor to evaluate and repair or replace as needed.

3.7.1 – Exhaust System Vents
Exhaust System Vents 1
FLUE PIPE CLEARANCE

A gas appliance flue pipe had improper clearance from combustible materials. This type of vent requires a minimum clearance of one inch. This condition is a potential fire hazard.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 4 – Exterior
4.2.1 – Driveways
Driveways 1
CRACKING – MINOR

Minor cracking was visible on the driveway in some areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.2 – Driveways
Driveways 2
DROPPED SURFACE/SLAB

The driveway has dropped or settled in areas, causing a steep or uneven step. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.3 – Driveways
Driveways 3
PITTED

The driveway surface was pitted in areas. A qualified contractor should evaluate and repair or replace as necessary.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

4.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 2
SWOLLEN – MOISTURE INTRUSION

The siding/trim had a swollen appearance due to moisture intrusion.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 3
Wall-Covering, Flashing & Trim 4
WOOD ROT

The siding and/or trim appeared to be rotted in areas. Recommend a qualified contractor to evaluate and repair or replace as necessary.

4.5.1 – Eaves, Soffits & Fascia

Eaves, Soffits & Fascia 1

DAMAGE – FASCIA

The fascia was damaged in one or more areas.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.7.1 – Electrical Fixtures
LOOSE – FIXTURE

One or more exterior fixtures were loose and not mounted securely. Recommend a qualified contractor to evaluate and repair or replace as needed.

4.8.1 – Electrical Outlets
Electrical Outlets 1
NO EXTERIOR GFCI PROTECTION

No Ground Fault Circuit Interrupter (GFCI) protection was provided for the exterior electrical outlets. Although GFCI protection of exterior circuits may not have been required at the time in which this property was built, modern building and safety standards now require them. This is a reflection of the current understanding of the potential hazards. The inspector recommends updating the existing exterior electrical circuits to include GFCI protection. A qualified contractor should evaluate and implement according to current standards.

4.8.2 – Electrical Outlets
LOOSE OUTLET

An exterior electrical outlet was loose in the wall. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.8.3 – Electrical Outlets
Electrical Outlets 2
MISSING WEATHERPROOF COVERING

The exterior electrical outlet was missing an in-use weatherproof covering. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.1 – Walkways
Walkways 1
TRIP HAZARD – WALKWAY(S)

A trip hazard was present on the walkway(s) in areas.  This condition is a safety concern. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
Vegetation, Grading & Drainage 2
NEGATIVE GRADING

The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation.  Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving, or settling, depending on soil composition, moisture content, and other conditions. The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters, and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.

4.12.2 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 3
TREE BRANCHES OVER PROPERTY

Large trees near the house have branches that overhang the property. Falling branches due to conditions such as wood decay, high winds, or heavy snow loads may cause injury, death, or damage. Significant weakening of large branches by conditions such as core decay may not be visible by persons without special training. Consider having these trees evaluated by a qualified arborist. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

4.14.1 – Exterior Faucets (Hose Bibs)
DRIPS AT KNOB

The outside water faucet drips at the knob when turned on. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.17.1 – Exterior Foundation Wall

Exterior Foundation Wall 1

Exterior Foundation Wall 2

CRACK – VERTICAL

The foundation had vertical cracks in areas. A qualified contractor should evaluate and repair as necessary before your inspection objection deadline.

4.19.1 – Decks & Balconies
Decks & Balconies 1
CRACKED, SPLIT WOOD – DECK

Cracked or split boards were present on the deck.  This condition could be considered a structural defect and potential safety hazard.

A qualified contractor should evaluate and repair or replace as necessary.

4.19.2 – Decks & Balconies
Decks & Balconies 2
PEELING PAINT – DECK

The exterior deck floor and/or other components were peeling paint. A qualified contractor should evaluate and repair or replace as necessary.

4.19.3 – Decks & Balconies
Decks & Balconies 3
INADEQUATELY SUPPORTED– STAIRS

Deck stairs were not adequately supported at the time of inspection. Recommend a qualified contractor to evaluate and repair replace as necessary.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
Roof Drainage - Downspouts & Extensions 2
MISSING – EXTENSIONS

The downspout (s) are missing the proper 6 ft. extensions. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 5 – Attached Garage
5.2.1 – Occupant Door
Occupant Door 1
DAMAGED – DOOR

An entry door in the garage area was damaged. A qualified contractor should evaluate and repair or replace as necessary.

5.2.2 – Occupant Door
Occupant Door 2
NOT FIRE RATED

The inspector was unable to verify that the door was fire rated. This may be considered a fire safety hazard. The door between the garage and the house should be a solid wood door at least 1-3/8 inches thick, a solid or honeycomb-core steel door at least 1-3/8 inches thick, or a 20-minute fire-rated door. This means that should a fire occur in the garage, the occupant door does not afford protection until firemen arrive. A qualified contractor should evaluate and repair or replace as necessary.

5.2.3 – Occupant Door
Occupant Door 3
NOT SELF CLOSING

The door between the garage and the living space failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazards and toxic fumes. A qualified contractor should evaluate and repair or replace as necessary.

5.9.1 – Stairs & Railings
Stairs & Railings 1
RISER TOO TALL, OVER 7 3/4″

The stair riser height is more than what is accepted for current safety standards.

The riser height maximum is 7 3/4 inches measured vertically between the stair treads. This poses a trip hazard.

Recommend a qualified contractor to evaluate and repair or replace as needed.

 6 – Interior, Doors, Windows
6.3.1 – Floors

Floors 1

CARPET STAINS

The carpet was stained in areas. A qualified contractor should evaluate and repair or replace as necessary.

6.6.1 – Electrical Outlets
Electrical Outlets 1
IMPROPER OUTLET

The outlet was not installed with a cover that is designed to be installed on a floor. A qualified contractor should evaluate, then repair or replace as advised.

6.8.1 – Stairways & Railings
Stairways & Railings 1
NOT CONTINUOUS

An interior handrail was not continuous throughout an interior stairway.

Handrails for stairs must be continuous for the full length of the stairway.

6.8.2 – Stairways & Railings
Stairways & Railings 1
SPINDLE SPACING OVER 4″

At the interior stairs, the handrail had spacing between components that were too far apart. Spacing of more than 4 ” could allow a child or pet to fall through. A fall or injury could occur if not corrected.  A qualified contractor should evaluate and repair or replace as necessary.

6.8.3 – Stairways & Railings
Stairways & Railings 2
MISSING GUARDRAIL

The landing lacked a guardrail. A fall/injury may occur if not corrected. A qualified contractor should evaluate, then repair or replace as advised.

 7 – Kitchen
7.6.1 – Electrical Outlets
Electrical Outlets 1
GFCI-NOT ALL PROTECTED

Ground fault circuit interrupter (GFCI) Protection was not provided for all kitchen electrical outlets. Although GFCI protection of kitchen outlets may not have been required at the time in which this property was built, as general knowledge of say fielding practices has improved with the passage of time building standards have changed to reflect current understanding.  A qualified contractor should evaluate and repair or replace as necessary.

7.9.1 – Faucets Fixtures
WOULD NOT SWIVEL

The kitchen sink faucet did not swivel at the time of the inspection. A qualified contractor should evaluate, then repair or replace as advised.

7.13.1 – Dishwasher
NOT OPERATIONAL

The dishwasher was not operational at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

 8 – Laundry
8.9.1 – Electrical Outlets
Electrical Outlets 1
GFCI PROTECTION IS NOT PRESENT

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

 9 – Bathroom
9.2.1 – Doors
SWINGS OPEN/CLOSED

The door swings open or closed by itself.  A qualified contractor should evaluate and repair or replace as necessary.

9.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
CLOGGED/SLOW – SINK DRAIN

The sink drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

9.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
LEAK – SHOWER HEAD

There was a leak at the shower head connection at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as necessary.

9.12.2 – Plumbing Fixtures
Plumbing Fixtures 2
LEAK – SINK FAUCET

The sink faucet leaked.  A qualified contractor should evaluate and repair or replace as necessary.

9.12.3 – Plumbing Fixtures
WATER NOT DIVERTED

The shower diverter did not divert all of the water to the shower and a stream of water passed through the bathtub spout when the shower was on.  A qualified contractor should evaluate and repair or replace as necessary.

 11 – Plumbing
11.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure is measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances are likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

 12 – Electrical
12.2.1 – Distribution Panels
Distribution Panels 1
MISSING – CIRCUIT LABELS

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power to.

Recommend a qualified contractor to verify the breakers and accuracy of any existing labeling as necessary.

12.2.2 – Distribution Panels
Distribution Panels 2
MISSING – MANUFACTURERS LABEL

The manufacturer’s label was missing, partial, or illegible on the electrical service panel. The manufacturer’s label typically provides information describing the main panel such as the name of the panel manufacturer, the panel model number, the panel amperage rating, limitations related to the environment in which the panel was designed to be installed, and grounding/bonding information for that particular model. The Inspector was unable to confirm the existence of proper conditions when confirmation would require information taken from this missing label.

12.2.3 – Distribution Panels
Distribution Panels 3
SCREWS MISSING – PANEL COVER

Screws/fasteners were missing at the electrical panel cover. A qualified contractor should evaluate and repair or replace as necessary.

 13 – Water Heating Equipment
13.1.1 – General Information
OLDER THAN 10 YEARS

The water heater was at or beyond its warranty and/or expected life expectancy.

The water heater age was determined by the photo included in this report. According to the U.S. Department of energy, these major appliances are intended to run for between 8 and 12 years. Be advised that every water heater will age differently relative to the following life span factors: water quality, mineral buildup, frequency of flushing, the volume of water utilized, size of the tank, brand, and quality of water heater. Although it was operating at the time of the inspection, the inspector can not determine the remaining life of the water heater.

 14 – Heating
14.5.1 – Gas Supply Shut-Off Valve
Gas Supply Shut-Off Valve 1
DIFFICULT TO ACCESS

The gas shut-off valve was difficult to access. A qualified contractor should evaluate, then repair or replace as advised.

14.7.1 – Condensate
Condensate 1
SECONDARY

The secondary drain line was capped or not routed to a drain. If the primary drain line becomes blocked, this condition could cause condensation to not drain properly and possibly damage the unit. The inspector recommends installing a secondary drain or installing an overflow protection device. A qualified contractor should evaluate and then repair or replace as advised.

 16 – Cooling
16.1.1 – Cooling System Information
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the cooling system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimated Life Expectancy Chart for Homes

16.1.2 – Cooling System Information
SERVICING RECOMMENDED

Based on the age of the cooling system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

16.3.1 – AC Compressor
AC Compressor 1
AC Compressor 2
AIR FLOW RESTRICTED

Airflow to the air-conditioner condenser coils was restricted by vegetation, dirt, or debris. The unit should be cleaned and anything restricting air flow in or around the air conditioner should be removed in order to maintain cooling system efficiency and avoid problems from overheating of the compressor.

16.3.2 – AC Compressor
AC Compressor 3
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings, and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.