The ridge shingles, used to protect areas of the roof from moisture intrusion, had exposed/inadequately sealed nails. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.
The vent flashing, used to protect areas of the roof from moisture intrusion, had exposed/inadequately sealed nails. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.
The driveway was deteriorated or eroded in some areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
The exterior of the garage door has one or more damaged panels. A qualified contractor should inspect and repair as necessary and according to current standards.
Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.
The siding/trim had a swollen appearance due to moisture intrusion.
Recommend a qualified contractor should evaluate and repair or replace as needed.
Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation. Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving, or settling, depending on soil composition, moisture content, and other conditions. The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters, and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.
There was an active wasp nest in one of the vent exhausts on the roof. A qualified contractor should evaluate and repair or replace as necessary.
The exterior deck floor and/or other components were peeling paint. A qualified contractor should evaluate and repair or replace as necessary.
The downspout (s) are missing the proper 6 ft. extensions. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
The garage door opener had a light bulb that was not working. Recommend a qualified contractor to evaluate and repair or replace as needed.
The photo-electric reverse sensors are installed too high from the garage floor surface.
The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.
The handrail is loose. This condition may be a safety hazard if not corrected.
Correction and further evaluation are recommended.
The ceilings showed signs of minor damage and wear. A qualified contractor should evaluate and repair or replace as necessary.
There was a gap in the hardwood floor outside the primary bedroom. A qualified contractor should evaluate and repair or replace as necessary.
The door was missing. A qualified contractor should evaluate and repair or replace as necessary.
The door would not latch when closed and may need adjustment at the strike plate to latch properly. A qualified contractor should evaluate and repair or replace as necessary.
Some windows had damaged or missing screens. A qualified contractor should evaluate and repair or replace as necessary.
The smoke detector was missing. A qualified person should replace them as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of the date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.
The kitchen countertop was chipped or damaged. A qualified contractor should evaluate and repair or replace as necessary.
Some windows had damaged or missing screens. A qualified contractor should evaluate and repair or replace as necessary.
The microwave handle was damaged or broken. A qualified contractor should evaluate and repair or replace as necessary.
The drain stop did not work or did not hold water in the tub. A qualified contractor should evaluate and repair or replace as necessary.
The bathtub drain stop was damaged, missing or did not operate properly. A qualified contractor should evaluate and repair or replace as necessary.
The electric meter security tag was missing or damaged. A qualified contractor should evaluate and repair or replace as necessary.
Some or all circuit breakers were a brand different from the main panel brand. Circuit breakers made by different manufacturers vary in design, therefore panel manufacturers require their own manufactured breakers to be used. Select brands are interchangeable, and there are some “semi” universal breaker types or panel types.
Using incompatible breakers in the panel of another manufacturer may result in poor connections which can create a potential fire or shock/electrocution hazard. A qualified contractor should evaluate and repair or replace as necessary.
Although an expansion tank or valve was not required when the water heater was installed it is recommended to add one after the water heater is replaced.
The water temperature was higher than the acceptable range of 120-130 degrees. We recommend adjusting the water heater thermostat.
The air-conditioner refrigerant suction line (large, insulated) exterior wall penetration should be sealed to prevent moisture and insect intrusion. A qualified contractor should evaluate and repair/replace as necessary.
The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings, and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
The inspector noticed late in the inspection that the upstairs did not appear to be cooling as well as the downstairs. The air conditioner was cooling properly but the air upstairs was not an acceptable cold temperature. A qualified contractor should evaluate and repair or replace as necessary.
The active ventilation fan was not working at the time of the inspection. A qualified contractor should evaluate and repair or replace as necessary.