2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
DAMAGED/DETERIORATED

The roof covering material showed minor damage/deterioration in some areas.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.4.1 – Flashing
Flashing 1
WALL FLASHING LOOSE

The wall flashing was loose. This condition could allow moisture to penetrate the exterior wall component. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.4.2 – Flashing
Flashing 2
RIDGE FLASHING EXPOSED NAILS

The ridge shingles, used to protect areas of the roof from moisture intrusion, had exposed/inadequately sealed nails. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.6.1 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 1
INADEQUATE CLEARANCE – ROOF

One or more combustion appliance exhaust flue(s) did not extend far enough above the roof. To ensure proper and safe operation, exhaust flues should extend at least 3 feet above the roof, and 2 feet above any portion of the roof within 10 feet (measured horizontally).  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

 3 – Attic, Insulation and Ventilation 
3.1.1 – Attic Access
DIFFICULT TO OPEN

The attic access hatch was tight and difficult to open. A qualified contractor should evaluate and repair or replace as necessary.

3.1.2 – Attic Access
Attic Access 1
Attic Access 2
HATCH NOT INSULATED

The attic access hatch was not properly insulated. A qualified contractor should evaluate and repair or replace as necessary.

3.4.1 – Insulation in Attic
Insulation in Attic 1
Insulation in Attic 2
NOT UNIFORM

The insulation is not uniform: thicker in areas, thinner in areas, or possibly missing in some areas.

Recommend a qualified contractor evaluate and repair or replace as needed.

3.4.2 – Insulation in Attic
TOO THIN

The insulation is thinner than current thermal resistance (R-value) standards.

Recommend a qualified contractor evaluate and repair or replace as needed.

 4 – Exterior
4.2.1 – Driveways
Driveways 1
CRACKING – MODERATE

The concrete driveway was moderately cracked. Cracks that progress to a separation of 1/4″ and more would be an indication of settlement, heaving, or structural problems. Cracks may present a tripping hazard. A qualified contractor should evaluate and repair as necessary.

4.2.2 – Driveways
Driveways 2
DETERIORATED

The driveway was deteriorated or was eroded in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.3 – Driveways
Driveways 3
DROPPED SURFACE/SLAB

The driveway has dropped or settled in areas, causing a steep or uneven step. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
Wall-Covering, Flashing & Trim 2
Wall-Covering, Flashing & Trim 3DETERIORATION

The exterior wall covering is beginning to deteriorate or has deteriorated.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 4
LOOSE – SIDING/TRIM

The exterior wall-covering material was loose in one or more areas.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 5
Wall-Covering, Flashing & Trim 6
Wall-Covering, Flashing & Trim 7
PEELING PAINT

Peeling paint was present in areas.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.4 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 8
Wall-Covering, Flashing & Trim 9SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

4.6.1 – Exterior Doors
Exterior Doors 1
DAMAGE – SCREEN DOOR

The screen door was damaged or deteriorated at the time of inspection.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.7.1 – Electrical Fixtures
Electrical Fixtures 1
Electrical Fixtures 2MISSING – COVER

An exterior light fixture or light was missing it’s cover. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

4.8.1 – Electrical Outlets
Electrical Outlets 1
GFCI – NOT ALL PROTECTED

Ground Fault Circuit Interrupter (GFCI) protection was not provided for all the exterior electrical outlets. Although GFCI protection of exterior circuits may not have been required at the time in which this property was built, modern building and safety standards now require them. This is a reflection of the current understanding of the potential hazards. The inspector recommends updating the existing exterior electrical circuits to include GFCI protection. A qualified contractor should evaluate and implement according to current standards.

4.11.1 – Walkways
Walkways 1
CRACKING – MINOR

Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
NEGATIVE GRADING

The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation.  Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving or settling, depending on soil composition, moisture content and other conditions.The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.

4.14.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
LOOSE IN WALL
LEFT

One or more exterior faucet was loose in the wall. The faucet should be securely fastened to the wall using appropriate screws depending on the material at the location of the faucet. Recommend a qualified contractor evaluate and repair or replace as needed.

 5 – Attached Garage
5.2.1 – Occupant Door
Occupant Door 1
DAMAGED – WEATHER STRIPPING

An entry door in the garage had damaged, missing, or loose weather stripping.

5.3.1 – Ceiling, Walls & Firewalls
Ceiling, Walls & Firewalls 1
I-BEAM MODIFIED

There was a large hole board through a structural I-beam in the garage. Support beams of this nature are never allowed to be modified. Further analysis by structural engineer is recommended.

5.4.1 – Floor
Floor 1
CRACKING – MODERATE

The concrete floor in the garage was moderately cracked. Cracks that progress to a separation of 1/4″ and more would be an indication of settlement, heaving, or structural problems. Cracks may present a tripping hazard. A qualified contractor should evaluate and repair as necessary.

5.6.1 – Door Opener
Door Opener 1
Door Opener 2
ELETRICAL WIRE

The electrical wire the power of the garage door opener outlet was hanging loose on the wall. In addition the outlet had no cover plate. A qualified contractor should evaluate and repair or replace as necessary.

5.7.1 – Electrical Outlets & Fixtures
Electrical Outlets & Fixtures 1
NO GFCI PROTECTION

The garage had one or more outlets without GFCI (or ground fault circuit interrupter) protection.

GFCI protection is required for all 15- and 20-amp receptacles, including outlets for refrigerators, sprinkler systems, garage door openers, and washing machines – some items may not be protected on purpose due to the potential for them to go unnoticed and cause damage. A qualified contractor should evaluate and repair or replace as necessary.

 6 – Interior, Doors, Windows
6.3.1 – Floors
Floors 1
HUMP
The floor had a noticeable hump or rise.  A qualified contractor should evaluate and repair or replace as necessary.
6.4.1 – Doors
Doors 1
Doors 2
LOOSE – HANDLE/KNOB
GUEST BEDROOMS

The door had a loose handle or knob.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.1 – Windows
Windows 1
SCREENS DAMAGED/MISSING
MULTIPLE

Some windows had damaged or missing screens.  A qualified contractor should evaluate and repair or replace as necessary.

6.8.1 – Stairways & Railings
Stairways & Railings 1
Stairways & Railings 2
MISSING – HANDRAIL

At the interior stairs, the handrail was missing.  A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

 7 – Kitchen
7.6.1 – Electrical Outlets
Electrical Outlets 1
GFCI-NOT ALL PROTECTED

Ground fault circuit interrupter (GFCI) Protection was not provided for all kitchen electrical outlets. Although GFCI protection of kitchen outlets may not have been required at the time in which this property was built, as general knowledge of say fielding practices has improved with the passage of time building standards have changed to reflect current understanding.  A qualified contractor should evaluate and repair or replace as necessary.

7.6.2 – Electrical Outlets
Electrical Outlets 2
FACEPLATE MISSING

An electrical outlet had a missing faceplate. A qualified contractor should evaluate and repair or replace as necessary.

7.7.1 – Windows
Windows 1
DIFFICULT TO OPEN/CLOSE

A window had a sash that was difficult to slide or operate to get opened/closed.  A qualified contractor should evaluate and repair or replace as necessary.

7.9.1 – Faucets Fixtures
Faucets Fixtures 1
WEAK PRESSURE/FLOW

The kitchen sink faucet had very weak pressure/flow. A qualified contractor should evaluate and repair or replace as necessary.

7.13.1 – Dishwasher
Dishwasher 1
NOT SECURED

The dishwasher was loose and not properly secured to the counter top or cabinets. A qualified contractor should evaluate and repair or replace as necessary.

7.15.1 – Range Hood
Range Hood 1
VENTS IN TO CABINET

The microwave vent hood vents in to the cabinet space between the top of the microwave and the cabinet above it. The microwave needs to be removed and the fan rotated forward to vent out of the top front vent on the microwave.  A qualified contractor should evaluate and repair or replace as necessary.

 8 – Laundry
8.1.1 – Laundry Room Location
LAUNDRY IN GARAGE

There was a partial laundry area installed in the garage. However so many components were missing you realistically could not do laundry. In addition the laundry room in the garage in Colorado is not recommended due to freezing temperatures. Also if you did install the washer and or dryer in the garage it would either block the door or prevent two cars from being parked inside. A qualified contractor should evaluate and repair or replace as necessary.

8.9.1 – Electrical Outlets
Electrical Outlets 1
OUTLET NOT WORKING

An electrical outlet was not working. A qualified contractor should evaluate and repair or replace as necessary.

8.10.1 – 220 Volt Dryer Outlet
220 Volt Dryer Outlet 1
NOT PRESENT

There was no 220 outlet installed in the laundry area. With no gas line no dryer could be used. A qualified contractor should evaluate and repair or replace as necessary.

8.11.1 – Dryer Vent Piping
NO VENT CONNECTION

No vent connection was provided for the dryer. Lack of proper dryer venting to the exterior may result in excessively high humidity levels which can damage property materials or components and may encourage the growth of microbes such as mold. Lack of proper dryer venting can also result in the accumulation of lint in the property. Lint is combustible and it’s accumulation is a potential fire hazard and a possible health hazard from the inhalation of particulates. The Inspector recommends proper installation of an Underwriter’s Laboratory (UL) approved dryer vent for safety reasons. Dryer vents should be clean annually to ensure that safe conditions continue to exist.

8.13.1 – Washer Drain
MISSING – DRAIN LINE

There was no washing machine drain line installed.  A qualified contractor should evaluate and repair or replace as necessary.

 9 – Bathroom
9.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
MISSING – TUB DRAIN STOPPER

The bathtub drain stop was damaged, missing or did not operate properly.  A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.5.1 – Floors
Floors 1
TILES LOOSE

Loose tiles are present at time of inspection. Recommend a qualified contractor repair or replace as necessary.

10.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
WATER NOT HOT

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate the mixing valve (safety feature to limit potential scalding) needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

Recommend a qualified contractor evaluate and repair or replace as necessary.

10.12.2 – Plumbing Fixtures
Plumbing Fixtures 2
BACKWARDS

The sink faucet control handles were installed backwards. A qualified contractor should evaluate and repair or replace as necessary.

 11 – Plumbing
11.1.1 – Main Water Shut-Off Valve
Main Water Shut-Off Valve 1
Main Water Shut-Off Valve 2
CORRODED – VALVE

The main water shutoff valve was corroded.

The valve is not and was not operated during the scope of a home  inspection.

Recommend a qualified contractor should evaluate and repair or replace as necessary.

11.3.1 – Water Supply & Distribution Systems
Water Supply & Distribution Systems 1
PEX NOT SECURED

The pecks piping in the crawlspace was not properly secured. It should be secured to framing every 32 inches. A qualified contractor should evaluate and repair or replace as necessary.

 12 – Electrical
12.2.1 – Distribution Panels
Distribution Panels 1
MISSING – CIRCUIT LABELS

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power too.

Recommend a qualified contractor verify the breakers and accuracy of any existing labeling as necessary.

12.2.2 – Distribution Panels
Distribution Panels 2
MISSING – MANUFACTURERS LABEL

The manufacturer’s label was missing, partial, or illegible at the  electrical service panel. The manufacturer’s label typically provides information describing the main panel such as the name of the panel manufacturer, the panel model number, the panel amperage rating, limitations related to the environment in which the panel was designed to be installed and grounding/bonding information for that particular model. The Inspector was unable to confirm the existence of proper conditions when confirmation would require information taken from this missing label.

 13 – Water Heating Equipment
13.5.1 – Draft Diverter & Exhaust Flue
Draft Diverter & Exhaust Flue 1
SINGLE WALL CLEARANCE 6″

The gas-fired water heater single wall exhaust flue had an improper clearance from combustible materials. This type of single wall vent requires a 6″ inch minimum clearance. This condition is a potential fire hazard. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

13.5.2 – Draft Diverter & Exhaust Flue
Draft Diverter & Exhaust Flue 2
DAMAGED VENT

The flexible exhaust flue installed at the water heater was damaged which will limit airflow. In addition, the inspector could not determine if this vent was proper for use with this type of water heater. A qualified contractor should evaluate and repair or replace as necessary.

13.6.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

13.8.1 – Temperature & Pressure Relief Valve
Temperature & Pressure Relief Valve 1
MISSING – PIPE

The temperature pressure relief valve was missing a pipe at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

13.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE HIGH

The water temperature was higher than the acceptable range of 120-130 degrees. This was corrected by the inspector during the inspection.

 14 – Heating
14.3.1 – Combustion Air Supply
OBSTRUCTED

The combustion air supply for this appliance was obstructed. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

14.9.1 – Air Filter
Air Filter 1
VERY DIRTY

The HVAC system air filter was very dirty or clogged. This condition reflects a lack of regular maintenance of the HVAC system. Clogged filters can restrict airflow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the heating and cooling system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing the filter, as well as cleaning, servicing, and evaluating the HVAC system by a qualified HVAC professional and repair or replace as necessary.

14.12.1 – Heating System Ignition & Operation

Heating System Ignition & Operation 1

Heating System Ignition & Operation 2

FLAMES

The heating system did fire and appeared to be in serviceable condition at the time of the inspection. However, the appearance of the flames during operation indicated that gas combustion was not correct. Cleaning, servicing and/or certification of the HVAC system by a qualified contractor is recommended and repaired or replaced as necessary.

 15 – Cooling
15.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
DAMAGED INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

 18 – Structural Crawlspace
18.2.1 – Soil Vapor Barrier
Soil Vapor Barrier 1
BARRIER DAMAGED

The crawlspace vapor barrier was damaged in some areas, which compromises its effectiveness in reducing moisture and/or radon levels. A qualified contractor should evaluate and repair or replace as necessary.

18.4.1 – Floor Structure & Supports
Floor Structure & Supports 1
OVER-EXTENDED JACK

A screw-jack was over extended beyond 3inches of exposed thread. This may weaken the structural capability of the support. Recommend a qualified contractor evaluate and repair or replace as needed.

18.6.1 – Insulation
Insulation 1
PAPER FACING WRONG WAY

Insulation installed in the crawlspace had paper or foil backing facing the wrong direction. Thermal insulation should always be installed with the paper or foil backing toward the source of heat. Reversal (backing on the cold side) may result in problems from the formation of excessive condensation. Excessive condensation may cause damage to property materials from decay or result in the development of microbial growth which can cause health problems in some people. A qualified contractor should evaluate and repair or replace as necessary.

18.7.1 – Ventilation
Ventilation 1
OBSTRUCTED

A crawlspace vent was obstructed or covered at the time of inspection. This may prevent proper ventilation into the crawlspace. Recommend a qualified contractor evaluate and repair or replace as needed.

 19 – Fireplace or Stove
19.1.1 – Fireplace Wood-Burning
Fireplace Wood-Burning 1
CLEANING NEEDED

The visible areas of the firebox and chimney flue were dirty at the time of the inspection. Most of the chimney flue was inaccessible and was not inspected. Dirty flues are potential fire hazards and should be cleaned by a professional. Recommend having the chimney evaluated by a C.S.I. (Chimney Safety Institute) -qualified chimney sweep.

19.1.2 – Fireplace Wood-Burning
Fireplace Wood-Burning 2
FIRE BRICKS CRACKED

The bricks in the fireplace were cracked in areas. A qualified contractor should evaluate and repair or replace as necessary.