3 – Attic, Insulation and Ventilation
3.1.1 – Attic Access
Attic Access 1
Attic Access 2
HATCH NOT INSULATED

The attic access hatch was not properly insulated. A qualified contractor should evaluate and repair or replace as necessary.

 4 – Exterior
4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

4.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 2
CONSTRUCTION IN PROGRESS

Construction still in progress at home at time of inspection. Recommend a qualified contractor further evaluate once construction is completed.

4.6.1 – Exterior Doors
Exterior Doors 1
DAMAGE – SCREEN DOOR

The screen door was damaged or deteriorated at the time of inspection.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.8.1 – Electrical Outlets
RESET OUTLET NOT LOCATED

As part of the normal home inspection the inspector tripped GFCI outlets. When the exterior outlets were tripped the master reset outlet could not be located. It is recommended to check with the builder to determine its location.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
NEGATIVE GRADING

The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation.  Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving or settling, depending on soil composition, moisture content and other conditions.The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
RECONNECT EXTENSION

Downspout(s) need to have extensions reconnected. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. When moisture is introduced to the foundation it could also cause possible mold growth. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 6 – Interior, Doors, Windows
6.7.1 – Electrical Fixtures & Switches
 Electrical Fixtures & Switches 1
LOOSE – LIGHT FIXTURE
1ST FLOOR

The light fixture was loose. A qualified contractor should evaluate and repair or replace as necessary.

 7 – Kitchen
7.12.1 – Food Waste Disposer
Food Waste Disposer 1
NOISY

The food waste disposer was noisy or damaged when operated. It may be that this appliance has an improper item stuck in it and it may be this appliance is worn or aged. A qualified contractor should evaluate and repair or replace as necessary.

7.13.1 – Dishwasher
Dishwasher 1
NOT FILLING WITH WATER

The dishwasher was not filling with water when on.  A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
MISSING – TUB DRAIN STOPPER

The bathtub drain stop was damaged, missing or did not operate properly.  A qualified contractor should evaluate and repair or replace as necessary.

 11 – Bathroom 3
11.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 2
NOT WORKING – SINK STOPPER

The drain stop did not work or did not hold water in the sink.  A qualified contractor should evaluate and repair or replace as necessary.

 12 – Bathroom 4
12.8.1 – Electrical Fixtures & Switches
WIRING DEFECT

Both switches in the bathroom control the light and fan indicating they are not wired properly. A qualified contractor should evaluate and repair or replace as necessary.

 13 – Plumbing
13.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure  measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

 16 – Heating
16.7.1 – Condensate
POPPING SOUND

The condensate drain appeared to be making a popping sound while the air conditioner was on. A qualified contractor should evaluate and repair or replace as necessary.