2 – Attic, Insulation and Ventilation
2.2.1 – Attic Structural Components
Attic Structural Components 1
ROOF DECKING SPLIT

The roof decking was split.  A qualified contractor should evaluate and repair or replace as necessary.

2.3.1 – Attic Moisture Intrusion
Attic Moisture Intrusion 1
Attic Moisture Intrusion 2
WATER INTRUSION

Signs of previous water penetration or intrusion into the attic. Water marks or stains were observed. Recommend asking seller if there’s any recent incidents that have been documented or mitigated.

Further evaluation is recommended.

2.4.1 – Insulation in Attic
Insulation in Attic 1
COMPRESSED – INSULATION

The insulation had been walked on or had stored items compressing it, which reduces the R-value.

Recommend a qualified contractor evaluate and repair or replace as needed.

2.6.1 – Electrical Wiring In Attic
Electrical Wiring In Attic 1
EXPOSED ELECTRICAL SPLICES

Exposed electrical conductor splices need to be installed inside a junction box with cover plate. A qualified contractor should evaluate and repair or replace as necessary.

4 – Attached Garage
4.2.1 – Occupant Door
Occupant Door 1
NOT FIRE RATED

The inspector was unable to verify that the door was fire rated . This may be considered a fire safety hazard. The door between the garage and the house should be a solid wood door at least 1-3/8 inches thick, a solid or honeycomb-core steel door at least 1-3/8 inches thick, or a 20-minute fire-rated door. This means that should a fire occur in garage, the occupant door does not afford protection until firemen arrive. A qualified contractor should evaluate and repair or replace as necessary.

4.2.2 – Occupant Door
Occupant Door 2
NOT SELF CLOSING

The door between the garage and the living space failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazard and toxic fumes. A qualified contractor should evaluate and repair or replace as necessary.

4.4.1 – Floor
Floor 1
CRACKING – COMMON

The concrete floor in the garage was cracked. Due to expansive soils, minor cracks are to be expected in the slabs or control joints. Recommend a qualified contractor evaluate and repair or replace as needed.

4.6.1 – Door Opener
Door Opener 1
Door Opener 2
EXTENSION CORD USED

An extension cord was being used to power the garage door operator. Extension cords are for temporary use only, and the operator should be plugged into a dedicated outlet. Recommend a qualified contractor evaluate and update to current building standards as necessary.

4.6.2 – Door Opener
Door Opener 3
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

4.9.1 – Stairs & Railings
Stairs & Railings 1
SPINDLE SPACING OVER 4”

Improper spacing was noted between balusters, spindles and rails. This is a safety hazard, especially for small children.

Guards may not allow the passage of a sphere 4 inches in diameter.

Correction and further evaluation is recommended.

5 – Interior, Doors, Windows
5.2.1 – Ceilings & Walls
Ceilings & Walls 1
ASBESTOS CEILING

The property had ceiling materials that may contain asbestos. Ceiling tiles or popcorn texture were manufactured or installed using asbestos as late as the early 90s.

In the past, asbestos fibers were added during the production to strengthen and increase durability. Materials that contain asbestos, when intact and in good condition, is generally considered non-friable and is not hazardous. Heat, water, weathering or aging can weaken asbestos materials to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.

5.2.2 – Ceilings & Walls
Ceilings & Walls 2
CRACKING AROUND WINDOW
PRIMARY BEDROOM

There was cracking around some windows on the interior (where the window meets the wall).  A qualified contractor should evaluate and repair or replace as necessary.

5.5.1 – Windows
Windows 1
SCREENS DAMAGED/MISSING
BACK RIGHT BEDROOM

Some windows had damaged or missing screens.  A qualified contractor should evaluate and repair or replace as necessary.

5.5.2 – Windows
Windows 2
DAMAGED – BLINDS
BACK LEFT BEDROOM

Window blinds were damaged at the time of inspection. This may be that the plastic was broken or missing or the blinds did not operate properly. Recommend a qualified contractor evaluate and repair or replace as needed.

5.6.1 – Electrical Outlets
Electrical Outlets 1
MISSING – FACEPLATE
LIVING ROOM

An electrical outlet had a missing faceplate. A qualified contractor should evaluate and repair or replace as necessary.

5.7.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
IMPROPER 3-WAY SWITCH
GARAGE STAIRWAY

A 3-way switch was improperly wired at the time of inspection, and one switch did not work when another one was turned on/off. Recommend a qualified contractor evaluate and repair or replace as needed. A 3-way switch is where a light fixture can be operated by more than one switch.

5.8.1 – Stairways & Railings
Stairways & Railings 1
SPINDLE SPACING OVER 4″
STAIRWAY

At the interior stairs, the handrail had spacing between components that were too far apart. Spacing of more than 4 ” could allow a child or pet to fall through. A fall or injury could occur if not corrected.  A qualified contractor should evaluate and repair or replace as necessary.

5.9.1 – Smoke & CO Detectors
CO DETECTOR MISSING
Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009 that requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage.

There are no carbon monoxide detectors on the lower or upper level.

5.9.2 – Smoke & CO Detectors
Smoke & CO Detectors 1
SMOKE DETECTOR NOT WORKING
BACK RIGHT BEDROOM

The smoke detector did not work when tested. A qualified person should repair or replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

5.11.1 – Fireplace Wood-Burning
Fireplace Wood-Burning 1
CLEANING NEEDED

The visible areas of the firebox and chimney flue were dirty at the time of the inspection. Most of the chimney flue was inaccessible and was not inspected. Dirty flues are potential fire hazards and should be cleaned by a professional. Recommend having the chimney evaluated by a C.S.I. (Chimney Safety Institute)

-qualified chimney sweep.

Upon opening the damper, a great deal of suit fell down into the fire box.

6 – Exterior – Condo/Townhome
6.1.1 – Walkways & Driveways
Walkways & Driveways 1
Walkways & Driveways 2
DAMAGE AT STEP
A step was damaged. This condition may be a safety hazard.

Correction and further evaluation is recommended.

6.1.2 – Walkways & Driveways
Walkways & Driveways 3
MINOR CRACKING – DRIVEWAY

Minor cracking was visible at the driveway. Monitoring is the minimum recommendation.

6.1.3 – Walkways & Driveways
Walkways & Driveways 4
EROSION

There is significant erosion of the grading underneath the back stoop. A qualified contractor should investigate and repair or replace as necessary.

6.5.1 – Electrical Outlets
Electrical Outlets 1
MISSING WEATHERPROOF COVERING

The exterior electrical outlet was missing a weatherproof covering. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

6.8.1 – Decks & Balconies
Decks & Balconies 1
CRACKED, SPLIT WOOD – DECK
BACK

Cracked or split boards were present at the deck.  This condition is a structural defect and potential safety hazard.

A qualified contractor should evaluate and repair or replace as necessary.

7 – Kitchen
7.5.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACKSPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

7.12.1 – Food Waste Disposer
Food Waste Disposer 1
MISSING WIRING CLAMP

The food waste disposer was missing the wiring connector (clamp and bushing).  A qualified contractor should evaluate and repair or replace as necessary.

7.13.1 – Dishwasher
Dishwasher 1
CYCLE SELECT NOT FUNCTIONING

The cycle select button on the dishwasher does not in fact select a cycle. No matter how many times the button is pushed it stays on the heavy setting. A qualified professional should investigate repair or replace as necessary.

8 – Laundry
8.3.1 – Clothes Washer/Dryer
ODOR
There is a very strong mildew smell coming from the washing machine at the time of the inspection.
8.9.1 – Electrical Outlets
Electrical Outlets 1
GFCI PROTECTION NOT PRESENT
LAUNDRY AREA

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

8.9.2 – Electrical Outlets
Electrical Outlets 2
FACEPLATE MISSING
LAUNDRY AREA

An electrical outlet had a missing faceplate. A qualified contractor should evaluate and repair or replace as necessary.

9 – Bathroom
9.9.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACK SPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

9.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
CLOGGED/SLOW – SINK DRAIN
UPSTAIRS BATHROOM

The sink drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

9.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
CHIPPED – TUB
UPSTAIRS BATHROOM

The bathtub finish was chipped or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

10 – Bathroom 2
10.4.1 – Ceilings & Walls
Ceilings & Walls 1
PAINT PEELING
DOWNSTAIRS BATHROOM

The paint was peeling in areas.  A qualified contractor should evaluate and repair or replace as necessary.

10.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
CLOGGED/SLOW – SINK DRAIN
DOWNSTAIRS BATHROOM

The sink drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

11 – Plumbing
11.3.1 – Water Supply & Distribution Systems
Water Supply & Distribution Systems 1
SADDLE VALVE
BASEMENT MECHANICAL ROOM

A saddle valve was present at the plumbing at the time of inspection. They are prone to leak over time as the rubber seal will eventually deteriorate and they clog up as calcium deposits build up at the small opening. Recommend a qualified contractor evaluate and replace it with a permanent valve as needed.

11.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure  measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

12 – Electrical
12.2.1 – Distribution Panels
Distribution Panels 1
Distribution Panels 2
MISSING – MANUFACTURERS LABEL

The manufacturer’s label was missing, partial, or illegible at the  electrical service panel. The manufacturer’s label typically provides information describing the main panel such as the name of the panel manufacturer, the panel model number, the panel amperage rating, limitations related to the environment in which the panel was designed to be installed and grounding/bonding information for that particular model. The Inspector was unable to confirm the existence of proper conditions when confirmation would require information taken from this missing label.

12.2.2 – Distribution Panels
Distribution Panels 3
SCREWS MISSING – PANEL COVER

Screws / fasteners were missing at the electrical panel cover. A qualified contractor should evaluate and repair or replace as necessary.

12.7.1 – Service Grounding & Bonding
Service Grounding & Bonding 1
GROUND ROD NOT FLUSH
BACK

The grounding rod is not flush with or below grade level. A qualified contractor should evaluate and repair or replace as necessary.

13 – Water Heating Equipment
13.3.1 – Pipe Connections
Pipe Connections 1
CORRODED – PIPE FITTINGS

Pipe fittings at the water heating equipment were corroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

13.6.1 – Combustion Air Supply
NOT PRESENT
The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

13.9.1 – Exterior Condition/Leakage
Exterior Condition/Leakage 1
RUSTED

The water heating equipment was rusted/corroded showing signs of previously leaking. A qualified contractor should evaluate and repair or replace as necessary.

13.9.2 – Exterior Condition/Leakage
Exterior Condition/Leakage 2
Exterior Condition/Leakage 3
WATER STAINS

There are water stains around the water heater that appear to be from the unit. This may be due to: an active leak in the tank or it’s pipe connections, excessive condensation, or the unit’s age. Recommend a qualified contractor evaluate and repair or replace as necessary.

13.10.1 – Drain Valve & Drip Pan
Drain Valve & Drip Pan 1
DRIP PAN DAMAGED

The drip pan for the water heating equipment was damaged. A qualified contractor should evaluate and repair or replace as necessary.

13.10.2 – Drain Valve & Drip Pan
Drain Valve & Drip Pan 2
HOSE ATTACHED TO DRAIN VALVE.

There is a hose extension attached to the drain valve. Although this in itself is not a defect, it does signal that there has been an issue in the past otherwise why would it be there. A qualified HVAC contractor should investigate and repair or replace as necessary.

13.12.1 – Operation & Response to Controls
Operation & Response to Controls 1
FLAMES

Flames were not entirely burning a blue color. Orange and yellow flames may be an indicator the fuel-air mixture is not right and gas may not be burning as efficiently as possible. Recommend a qualified contractor evaluate to adjust, repair, or replace fuel-burning components as necessary.

14 – Heating
14.9.1 – Air Filter
Air Filter 1
DIRTY
The HVAC system air filter was dirty. Clogged filters can restrict airflow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing the filter, as well as cleaning, servicing, and evaluating the HVAC system by a qualified HVAC professional and repair or replace as necessary.