2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
Roof Covering 2
Roof Covering 3
DAMAGED/DETERIORATED

The roof covering material was damaged/deteriorated in some areas.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.3.1 – Roof Structure
Roof Structure 1
RIDGE/RAFTER SAG

The inspector observed that the roof ridge/rafter sagged visibly. This condition could increase unless the structural problem is corrected. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.3.2 – Roof Structure
DECKING DEFLECTION

The inspector observed deflection of the roof decking in some areas was noted. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.4.1 – Flashing
Flashing 1
WALL FLASHING DAMAGED

The wall flashing was bent/damaged in areas.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.5.1 – Plumbing Vent Pipes
Plumbing Vent Pipes 1
Plumbing Vent Pipes 2
Plumbing Vent Pipes 3
TOO SHORT

A plumbing vent did not extend far enough above the roof. A plumbing vent should extend a minimum of 10″.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.6.1 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 1
Flue Gas Vent Pipes 2
INADEQUATE CLEARANCE – ROOF

One or more combustion appliance exhaust flue(s) did not extend far enough above the roof. To ensure proper and safe operation, exhaust flues should extend at least 3 feet above the roof, and 2 feet above any portion of the roof within 10 feet (measured horizontally).  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.6.2 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 3
DENTED/DAMAGED

The combustion exhaust flue was dented/damaged at the time of the inspection. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.7.1 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 2
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4 – Exterior
4.2.1 – Driveways
Driveways 1
Driveways 2
HEAVING AND/OR SETTLING

The driveway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose, or it can no longer support the weight causing it to sink or crack. This condition could potentially cause a trip hazard.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
DAMAGED – SIDING

The siding and/or trim was damaged in areas of the exterior.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 2
Wall-Covering, Flashing & Trim 3
PENETRATIONS

There were penetrations in areas of the siding at the time of inspection. Recommend applying appropriate sealant to these areas to prevent potential moisture or pest intrusion. A qualified contractor should further evaluate and repair or replace as necessary.

4.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 4
WARPED – VINYL

Vinyl siding was warped in areas. This is a somewhat common issue that should be monitored and if it’s excessive a Qualified contractor should evaluate and repair or replace as needed.

4.4.4 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 5
SIDING WAVY

Some of the exterior siding has a wavy appearance.  A qualified contractor should evaluate and repair or replace as necessary according to current standards.

4.8.1 – Electrical Outlets
Electrical Outlets 1
NO EXTERIOR GFCI PROTECTION

No Ground Fault Circuit Interrupter (GFCI) protection was provided for the exterior electrical outlets. Although GFCI protection of exterior circuits may not have been required at the time in which this property was built, modern building and safety standards now require them. This is a reflection of the current understanding of the potential hazards. The inspector recommends updating the existing exterior electrical circuits to include GFCI protection. A qualified contractor should evaluate and implement according to current standards.

4.8.2 – Electrical Outlets
Electrical Outlets 2
WIRING

The wiring did not appear to properly installed. extension cord being used as permanent wiring. Recommend qualified contractor repair and replace as necessary.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
TREE LIMBS CONTACT ROOF

The tree limbs that are in contact with the roof or hanging near the roof should be trimmed. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor evaluate and repair or replace as necessary.

4.19.1 – Decks & Balconies
Decks & Balconies 1
Decks & Balconies 2
CRACKED, SPLIT WOOD – DECK

Cracked or split boards were present at the deck.  This condition is a structural defect and potential safety hazard.

A qualified contractor should evaluate and repair or replace as necessary.

4.19.2 – Decks & Balconies
Decks & Balconies 3
Decks & Balconies 4
LEANING – POST

A support post was leaning at the deck. A qualified contractor should evaluate and repair or replace as necessary.

4.20.1 – Railings & Handrails
Railings & Handrails 1
HORIZONTAL RAILINGS

The guard/hand rail had horizontal railings. This creates a climbing risk and a fall or injury could occur if not corrected. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

4.20.2 – Railings & Handrails
Railings & Handrails 2

Railings & Handrails 3

SPINDLE SPACING OVER 4″

Improper spacing was noted between balusters, spindles and rails. This is a safety hazard, especially for small children.

Guards may not allow the passage of a sphere 4 inches in diameter.

Correction and further evaluation is recommended.

4.20.3 – Railings & Handrails
Railings & Handrails 4
STAIR-RAILING GAP OVER 6″

Improper gap between stairs and railing.  This is a safety hazard, especially for small children.

An opening, on the open side of a stairs, and bottom rail of the guard should not allow the passage of a sphere 6 inches in diameter.

Correction and further evaluation is recommended.

4.20.4 – Railings & Handrails
Railings & Handrails 5
Railings & Handrails 6
STAIR RAIL NOT 34″

Railing height at the stairs was measured less than 34 inches.

Railings on the open side of a stairway must be at least 34 inches in height above any portion of the walking surface.

Correction and further evaluation is recommended.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
Roof Drainage - Downspouts & Extensions 2
EXTENSIONS TOO SHORT

One or more down spout extensions were too short. Recommend installing 6-8ft long (or greater as needed) extensions to divert rainwater runoff away from the property.

4.21.2 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 3
Roof Drainage - Downspouts & Extensions 4
MISSING – EXTENSIONS

Downspout(s) are missing the proper 6 ft. extensions. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5 – Interior, Doors, Windows
5.3.1 – Floors
Floors 1
HUMP

The floor had a noticeable hump or rise.  A qualified contractor should evaluate and repair or replace as necessary.

5.3.2 – Floors
Floors 2
FLOOR SQUEAKS

The floor squeaks when stepped on.  A qualified contractor should evaluate and repair or replace as necessary.

5.4.1 – Doors
Doors 1
RUBS FRAME

An interior door rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly.

A qualified contractor should evaluate and repair or replace as necessary.

5.4.2 – Doors
Doors 2
RUBS FLOOR

An interior door rubs on the flooring when opening or closing. Recommend a qualified contractor evaluate and repair or replace as needed.

5.5.1 – Windows
Windows 1
MISSING GLASS

The window was missing a glass pane.  A qualified contractor should evaluate and repair or replace as necessary.

5.5.2 – Windows
Windows 2
Windows 3
SCREENS DAMAGED/MISSING

Some windows had damaged or missing screens.  A qualified contractor should evaluate and repair or replace as necessary.

5.9.1 – Smoke & CO Detectors

Smoke & CO Detectors 1

Smoke & CO Detectors 2
Smoke & CO Detectors 3
SMOKE DETECTOR MISSING

The smoke detector was missing. A qualified person should replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

6 – Kitchen
6.12.1 – Food Waste Disposer
Food Waste Disposer 1
MISSING WIRING CLAMP

The food waste disposer was missing the wiring connector (clamp and bushing).  A qualified contractor should evaluate and repair or replace as necessary.

6.13.1 – Dishwasher
Dishwasher 1
Dishwasher 2
DOOR RUBS CABINET/WALL

The dishwasher door rubbed the adjacent wall or cabinet when opening or closing.  A qualified contractor should evaluate and repair or replace as necessary.

6.14.1 – Range/Oven/Cooktop
Range/Oven/Cooktop 1
GAS LEAK

There was a gas leak at the stove/cook top.  A qualified contractor should evaluate and repair or replace as necessary.

8 – Bathroom
8.2.1 – Doors
Doors 1
SWINGS OPEN/CLOSED

The door swings open or closed by itself.  A qualified contractor should evaluate and repair or replace as necessary.

8.9.1 – Cabinets & Counters
Cabinets & Counters 1
DAMAGED – CABINET FLOOR

The cabinet floor was damaged. This may be from excessive leaking pipes, condensation, or even leaking cleaners stored in cabinet over the years.

A qualified contractor should evaluate and repair or replace as necessary.

8.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
CLOGGED/SLOW – TUB/SHOWER DRAIN

The tub/shower drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

8.14.1 – Tub, Shower Area
Tub, Shower Area 1
CAULK – NEEDS TOUCH-UPS

Some caulking in the tub shower area was loose, old, or poorly done. Recommend a qualified contractor evaluate and re-caulk as needed.

9 – Bathroom 2
9.13.1 – Toilets
Toilets 1
LOOSE AT THE FLOOR

The toilet was loose at the floor. This condition typically is caused by loose bolts or nuts and/or missing floor seals. Loose toilet can result in leaks, water damage, and mold, as well as damage to the toilet, water supply lines, bolts, and drainage pipes. A qualified contractor should evaluate and repair or replace as necessary.

13 – Heating
13.1.1 – Heating System Information
Heating System Information 1
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

13.7.1 – Condensate
Condensate 1
CONDENSATE DISCHARGE SHOULD BE EXTENDED

The condensate discharge pipe should be extended so that the water is diverted far enough away from the house foundation. A qualified contractor should evaluate and repair or replace as necessary.

15 – Structural Crawlspace
15.3.1 – Moisture Intrusion
Moisture Intrusion 1
EXCESSIVE GROUND MOISTURE

Areas of the crawlspace were visibly wet or soft/squishy under the vapor barrier. The ground showed signs of moisture intrusion. A qualified contractor should evaluate and repair or replace as necessary.

15.3.2 – Moisture Intrusion
Moisture Intrusion 2
WATER DAMAGE AROUND PLUMBING

Water damage was visible in the crawlspace floor structure around plumbing lines. There may be a past or current leak in the nearby drain or supply lines that could further stain or rot wood if not corrected.