A bulb at an exterior light fixture did not respond to the switch at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

Cracking or separation was present at the concrete step(s) in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

The lawn sprinkler system supply valves appeared to be corroded and/or leaking at time of inspection. A qualified contractor should evaluate and repair/replace as necessary according to current standards.

The outside water faucet is connected to a garden hose. The hose could not be removed to inspect the faucet’s current operation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.


The exterior hose bib dripped from the anti-siphon when operated.

One or more downspout extensions were not properly positioned. Extensions should be properly attached with a proper slope to guide run-off 5 feet away from the foundation structure.
Recommend a qualified contractor evaluate and repair or replace as necessary.

The garage door was hard to lift or the spring(s) did not support the weight of the door when tested.
Recommend a qualified contractor evaluate and repair or replace as necessary.

The stairs in the garage were sloped toward the occupant door of the home. A qualified contractor should investigate and repair or replace as necessary.

The floors showed signs of minor damage and wear, particularly in high-traffic areas. A qualified contractor should evaluate and repair or replace as necessary.

The laundry area exhaust fan was dirty. The fan could eventually become clogged or damaged if not cleaned. A qualified contractor should evaluate and repair or replace as necessary.

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace as necessary.

There are many dead hornets in the furnace cabinet. Likely a vent needs to be screened on the outside.

The Crawlspace opening is missing a handle and is difficult to open. A qualified contractor is recommended to evaluate and repair or replace as needed.