Home Inspection Brookline Ct Colorado Springs CO

Sub Heading - ACF

Highlights

Inspection Detail Roof 1 Attic, Insulation, and Ventilation Exterior 31 Attached Garage 6 Interior, Doors, Windows 18 Kitchen 13 Laundry 4 Bathroom 4 Bathroom 2…

Share:

 2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
DAMAGED/DETERIORATED
FRONT

The roof covering material was damaged/deteriorated in some areas.  A qualified contractor should evaluate and repair or replace as necessary.

 4 – Exterior
4.2.1 – Driveways
Driveways 1
Driveways 2
Driveways 3
CRACKING – MINOR

Minor cracking was visible on the driveway in some areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.2 – Driveways
Driveways 4
Driveways 5
HEAVING AND/OR SETTLING

The driveway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose, or it can no longer support the weight causing it to sink or crack. This condition could potentially cause a trip hazard.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.3.1 – Garage Door Exterior

Garage Door Exterior 1

Garage Door Exterior 2

GAP AROUND DOOR

The door had an opening that was too wide leaving a gap or daylight around the door.  A qualified contractor should evaluate and repair or replace as necessary.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
PENETRATIONS

There were penetrations in areas of the siding at the time of inspection. Recommend applying the appropriate sealant to these areas to prevent potential moisture or pest intrusion. A qualified contractor should further evaluate and repair or replace as necessary.

4.4.2 – Wall-Covering, Flashing & Trim

Wall-Covering, Flashing & Trim 2

MISSING – PAINT

The siding and/or trim in areas were missing paint.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 3
SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

4.4.4 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 4
Wall-Covering, Flashing & Trim 5

Wall-Covering, Flashing & Trim 6

SWOLLEN – MOISTURE INTRUSION

The siding/trim had a swollen appearance due to moisture intrusion.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.5 – Wall-Covering, Flashing & Trim

Wall-Covering, Flashing & Trim 8

WOOD ROT

The siding and/or trim appeared to be rotted in areas. Recommend a qualified contractor evaluate and repair or replace as necessary.

4.6.1 – Exterior Doors

Exterior Doors 1

DAMAGE – WEATHER STRIPPING

An entry door had damaged or deteriorated weather stripping at the time of the inspection. A qualified contractor should evaluate, then repair or replace as advised.

4.6.2 – Exterior Doors
Exterior Doors 2
MISSING – SCREEN DOOR
BACK

A screen door was missing at the time of inspection.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.8.1 – Electrical Outlets

Electrical Outlets 1

MISSING WEATHERPROOF COVERING

The exterior electrical outlet was missing a weatherproof covering. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.9.1 – Windows

Windows 1

Windows 2

Windows 3

DAMAGED – FRAME

The window frame was damaged. A qualified contractor should evaluate and repair or replace as necessary.

4.9.2 – Windows
Windows 4
MISSING – SCREEN

A window was missing a window screen.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.9.3 – Windows

Windows 5

WOOD ROT AT WINDOW

An exterior window has trim or framing that appears to have wood rot. This may represent a general lack of maintenance or potential water intrusion issues.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.1 – Walkways

Walkways 1

CRACK AT STEP(S)

Cracking or separation was present at the concrete step(s) in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.2 – Walkways

Walkways 2

CRACKING – MINOR

Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.3 – Walkways
Walkways 3
HEAVING AND/OR SETTLING

The walkway(s) showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose or it can no longer support the weight causing it to sink or crack.

  • This causes cracks in the concrete.
  • This creates trip hazards that could result in injury.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage

Vegetation, Grading & Drainage 1

NEGATIVE GRADING

The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation.  Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving, or settling, depending on soil composition, moisture content, and other conditions. The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters, and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.

4.12.2 – Vegetation, Grading & Drainage

Vegetation, Grading & Drainage 2

VINES ON SIDING

Vegetation growing on siding should be removed and kept away from eaves, woodwork, doors, chimneys, or other building components. They hold moisture against the wall, hide rot and other problems, and are conducive conditions for termites, carpenter ants,  etc. The growth does not allow full inspection of the siding and can hide potential defects underneath.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

4.14.1 – Exterior Faucets (Hose Bibs)
LEAKS AT ANTI-SIPHON
FRONT

The exterior hose bib dripped from the anti-siphon when operated.

4.17.1 – Exterior Foundation Wall

Exterior Foundation Wall 1

CRACKS – AT CORNER(S)

The exterior foundation wall had cracks at the corner. A qualified contractor should evaluate and repair or replace as necessary.  Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540 or online at www.axiuminspections.com/structural-engineer.

4.17.2 – Exterior Foundation Wall

Exterior Foundation Wall 2

CRACK – SETTLEMENT
FRONT GARAGE

The exterior foundation wall had settlement crack(s.) A qualified contractor should evaluate and repair or replace as necessary. Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540 or online at www.axiuminspections.com/structural-engineer.

4.19.1 – Decks & Balconies
Decks & Balconies 1
CRACKED, SPLIT WOOD – DECK

Cracked or split boards were present on the deck.  This condition is a structural defect and potential safety hazard.

A qualified contractor should evaluate and repair or replace as necessary.

4.19.2 – Decks & Balconies
Decks & Balconies 2
DETERIORATED – STRUCTURE

There were deteriorated structural components visible on the deck. Depending on the severity of the deterioration, the use of the deck should be cautiously monitored.

A qualified contractor should evaluate and repair or replace as necessary.

4.19.3 – Decks & Balconies
Decks & Balconies 3
Decks & Balconies 4
LOOSE – RAILING

Railings were loose at the exterior deck at the time of inspection. recommend a qualified contractor evaluate and repair or replace as needed.

4.19.4 – Decks & Balconies
Decks & Balconies 5
MISSING – LEDGER FLASHING

Flashing was missing from the ledger board. This flashing problem may allow water to enter the wall cavity or building components. A qualified contractor should evaluate and repair or replace as necessary.

4.19.5 – Decks & Balconies
Decks & Balconies 6
PEELING PAINT – DECK

The exterior deck floor and/or other components were peeling paint. A qualified contractor should evaluate and repair or replace as necessary.

4.19.6 – Decks & Balconies
Decks & Balconies 7
Decks & Balconies 8
WOOD ROT – FLOORING, SUPPORTS

Rotted or deteriorated wood was visible on the deck flooring and/or supports.  This condition is a structural defect and a safety hazard if not corrected.

A qualified contractor should evaluate and repair or replace as necessary.

4.20.1 – Railings & Handrails
Railings & Handrails 1
Railings & Handrails 2
LOOSE – HANDRAIL
BACK

The guard/handrail was loose and should be secured. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

4.21.1 – Roof Drainage – Downspouts & Extensions

Roof Drainage - Downspouts & Extensions 1

MISSING – EXTENSIONS

The downspout (s) are missing the proper 6 ft. extensions. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.21.2 – Roof Drainage – Downspouts & Extensions

Roof Drainage - Downspouts & Extensions 2

RECONNECT EXTENSION

The downspout (s) need to have extensions reconnected. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. When moisture is introduced to the foundation it could also cause possible mold growth. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 5 – Attached Garage
5.2.1 – Occupant Door
Occupant Door 1
NOT FIRE RATED
MISSING THE FIRE-RATED LABELING

The inspector was unable to verify that the door was fire rated. This may be considered a fire safety hazard. The door between the garage and the house should be a solid wood door at least 1-3/8 inches thick, a solid or honeycomb-core steel door at least 1-3/8 inches thick, or a 20-minute fire-rated door. This means that should a fire occur in the garage, the occupant door does not afford protection until firemen arrive. A qualified contractor should evaluate and repair or replace as necessary.

5.2.2 – Occupant Door
Occupant Door 2
NOT SELF CLOSING

The door between the garage and the living space failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazards and toxic fumes. A qualified contractor should evaluate and repair or replace as necessary.

5.4.1 – Floor
Floor 1
HEAVING/SETTLING

Indications of movement from the heaving/settling of the concrete floor were present in the garage. Significant movement may compromise the structural integrity of the foundation or structure of the garage which only a qualified structural engineer could comment on after further analysis.

Recommend a qualified structural engineer to inspect further and provide a professional opinion related to this observation.

Axium recommends our premier partner – Level Engineering. They can be contacted at 720-400-8148 or online at www.axiuminspections.com/structural-engineer.

5.5.1 – Vehicle Door
Vehicle Door 1
WEAK SPRINGS

The garage door was hard to lift or the spring(s) did not support the weight of the door when tested.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

5.7.1 – Electrical Outlets & Fixtures
Electrical Outlets & Fixtures 1
MISSING – FACEPLATE
GARAGE

An outlet or switch box in the garage was missing a faceplate cover. This may be a shock hazard. Recommend a qualified contractor install the missing piece.

5.7.2 – Electrical Outlets & Fixtures
Electrical Outlets & Fixtures 2
Electrical Outlets & Fixtures 3
OUTLET HOT AND NEUTRAL REVERSED
GARAGE

One or more electrical outlet(s) were wired incorrectly with the hot and neutral wires being reversed. While the outlet still provides power to electronic equipment, a shock hazard has been created as there is still electricity running through the hot wire when the switch is off. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

 6 – Interior, Doors, Windows
6.2.1 – Ceilings & Walls
Ceilings & Walls 1
CRACKING AROUND WINDOW

There was cracking around some windows on the interior (where the window meets the wall).  A qualified contractor should evaluate and repair or replace as necessary.

6.2.2 – Ceilings & Walls

Ceilings & Walls 2

DAMAGED – WALLS

The walls showed signs of minor damage and wear.  A qualified contractor should evaluate and repair or replace as necessary.

6.2.3 – Ceilings & Walls

Ceilings & Walls 3

MOISTURE DAMAGE-WALLS

The interior walls showed evidence that moisture was entering from behind possibly including damage and deterioration.  A qualified contractor should evaluate and repair or replace as necessary.

6.2.4 – Ceilings & Walls

Ceilings & Walls 4

MINOR CRACKS-CEILING

Minor cracking was visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

6.2.5 – Ceilings & Walls

Ceilings & Walls 5

NAIL POPS-CEILINGS

There were “nail pops” visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

6.3.1 – Floors

Floors 1

CARPET LOOSE

The carpet was loose or baggy and may need to be restretched.  A qualified contractor should evaluate and repair or replace as necessary.

6.3.2 – Floors

Floors 2

DAMAGED – FLOOR COVERING

There appeared to be some damage to the interior flooring in areas. Recommend a qualified contractor to evaluate and repair or replace as needed.

6.3.3 – Floors

Floors 3

FLOOR NOT SEALED AT EDGE

The floor covering was not sealed at the edges and may allow moisture intrusion.  A qualified contractor should evaluate and repair or replace as necessary.

6.3.4 – Floors

Floors 4

FLOOR SQUEAKS

The floor squeaks when stepped on.  A qualified contractor should evaluate and repair or replace as necessary.

6.3.5 – Floors

Floors 5

WEAR AND TEAR
THROUGHOUT PROPERTY

The floors showed signs of minor damage and wear, particularly in high-traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

6.4.1 – Doors

Doors 1

DAMAGED – DOOR

The door surface was damaged.  A qualified contractor should evaluate and repair or replace as necessary.

6.4.2 – Doors

Doors 2

LOOSE – HINGE

The door had one or more loose hinges.  A qualified contractor should evaluate and repair or replace as necessary.

6.6.1 – Electrical Outlets

Electrical Outlets 1

LOOSE – OUTLET

An electrical outlet was loose in the wall. A qualified contractor should evaluate and repair or replace as necessary.

6.7.1 – Electrical Fixtures & Switches

Electrical Fixtures & Switches 1

Electrical Fixtures & Switches 2

NOT WORKING – BULB(S)

One or more light bulbs were not working at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as needed.

6.8.1 – Stairways & Railings
Stairways & Railings 1

Stairways & Railings 2

LOOSE – HANDRAIL

At the interior stairs, the handrail was loose.  A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

6.9.1 – Smoke & CO Detectors
CO DETECTOR MISSING
1ST FLOOR GAS LP FIREPLACE AND WATER HEATER LOCATED ON THE FIRST FLOOR

Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends the installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009, which requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage.

There are no carbon monoxide detectors on the lower or upper levels.

6.11.1 – Fireplaces Gas/LP
Fireplaces Gas/LP 1
Fireplaces Gas/LP 2
FIREPLACE NOT OPERATIONAL
GAS VALVE OFF

The gas fireplace did not respond to available controls and was not operational. A qualified contractor should evaluate and repair or replace as necessary.

6.11.2 – Fireplaces Gas/LP
Fireplaces Gas/LP 3
FIREPLACE – DIRTY

Excessive lint, dust, and/or debris were built up in the pilot ignition compartment. Recommend further evaluation and proper cleaning by a qualified professional.

 7 – Kitchen
7.2.1 – Doors
Kitchen Doors 1
DAMAGED – DOOR
KITCHEN PANTRY DOOR

The door surface was damaged.  A qualified contractor should evaluate and repair or replace as necessary.

7.4.1 – Floors
Floors 1
WEAR AND TEAR
KITCHEN

The floors showed signs of minor damage and wear – particularly in high-traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

7.5.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – SINK

The countertop needs caulking with silicone around the sink.  A qualified contractor should evaluate and repair or replace as necessary.

7.5.2 – Cabinets & Counters
Cabinets & Counters 2
DAMAGED – CABINET FLOOR
KITCHEN

The cabinet floor was damaged. This may be from excessive leaking pipes, condensation, or even leaking cleaners stored in cabinets over the years.

A qualified contractor should evaluate and repair or replace as necessary.

7.5.3 – Cabinets & Counters
Cabinets & Counters 3
WORN FINISH

Counters or cabinetry had a finish that was worn or peeling. Recommend a qualified contractor to evaluate and repair or replace as needed.

7.7.1 – Windows

Windows 1

Windows 2
Windows 3
SIGNS OF REPAIRS
KITCHEN

One of the non-functioning windows next to the kitchen has busted sealant or has been repaired with additional caulking.

7.9.1 – Faucets Fixtures
Faucets Fixtures 1
SINK-CHIPPED/DAMAGED FINISH
KITCHEN

The sink finish was chipped or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

7.9.2 – Faucets Fixtures
Faucets Fixtures 2
FAUCET NOT SECURED AT MOUNT
KITCHEN

The sink faucet was not soundly secured to the counter and was loose or weak at the mount. Recommend a qualified contractor to evaluate and repair or replace as needed.

7.9.3 – Faucets Fixtures
Faucets Fixtures 3
SPRAYER STUCK ON SPRAY MODE

The sink sprayer sticks on spray mode.  A qualified contractor should evaluate and repair or replace as necessary.

7.12.1 – Food Waste Disposer
Food Waste Disposer 1
MISSING WIRING CLAMP

The food waste disposer was missing the wiring connector (clamp and bushing).  A qualified contractor should evaluate and repair or replace as necessary.

7.13.1 – Dishwasher
Dishwasher 1
CONTROL PANEL DAMAGED
MINOR CRACK FRONT DOOR CONTROL PANEL

The dishwasher control panel was illegible, inoperable, or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

7.14.1 – Range/Oven/Cooktop

Range/Oven/Cooktop 1

DAMAGED DISPLAY

The oven display was damaged in somewhat illegible at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as needed

7.15.1 – Range Hood
Range Hood 1
THE LIGHT DID NOT WORK

The vent hood light was not working at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

 8 – Laundry
8.2.1 – Doors
Laundry doors 1
MISSING – DOOR
LAUNDRY AREA

The door was missing.  A qualified contractor should evaluate and repair or replace as necessary.

8.5.1 – Ceilings & Walls
Ceilings & Walls1
Ceilings & Walls 2
DAMAGED – WALLS
MINOR DAMAGE BEHIND WASHER DRYER WALL

The walls showed signs of minor damage and wear.  A qualified contractor should evaluate and repair or replace as necessary.

8.8.1 – Floors
FLOOR NOT SEALED AT EDGE
LAUNDRY AREA

The floor covering was not sealed at the edges and may allow moisture intrusion.  A qualified contractor should evaluate and repair or replace as necessary.

8.9.1 – Electrical Outlets
GFCI PROTECTION IS NOT PRESENT
LAUNDRY AREA

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

 9 – Bathroom
9.4.1 – Ceilings & Walls

DAMAGED – TRIM
SOME AREAS THROUGHOUT THE PROPERTY

Baseboard or accent trim was damaged at areas of the bathroom walls at the time of inspection.

Recommend a qualified contractor to evaluate and repair or replace as needed.

9.4.2 – Ceilings & Walls

SIGNS OF REPAIR-WALLS

The walls had signs of a previous repair.  A qualified contractor should evaluate and repair or replace as necessary.

9.5.1 – Floors
FLOOR NOT SEALED AT EDGE
1ST FLOOR BATHROOM

The floor covering was not sealed at the edges and may allow moisture intrusion.  A qualified contractor should evaluate and repair or replace as necessary.

9.9.1 – Cabinets & Counters
WORN FINISH
1ST FLOOR BATHROOM

Wood cabinetry had a finish that was worn or peeling. Recommend a qualified contractor to evaluate and repair or replace as needed.

 10 – Bathroom 2
10.4.1 – Ceilings & Walls

MOISTURE DAMAGE-WALLS
PRIMARY BATHROOM

The interior walls showed evidence that moisture was entering from behind possibly including damage and deterioration.  A qualified contractor should evaluate and repair or replace as necessary.

10.5.1 – Floors
FLOOR NOT SEALED AT EDGE

The floor covering was not sealed at the edges and may allow moisture intrusion.  A qualified contractor should evaluate and repair or replace as necessary.

10.7.1 – Electrical Outlets
LOOSE – OUTLET
PRIMARY BATHROOM

An electrical outlet was loose in the wall. A qualified contractor should evaluate and repair or replace as necessary.

10.8.1 – Electrical Fixtures & Switches
MISSING – BULB
PRIMARY BATHROOM

The light fixture was missing one or more bulbs. A qualified contractor should evaluate and repair or replace as necessary.

10.9.1 – Cabinets & Counters
SIGNS OF REPAIR

The cabinetry had signs of the previous repair.  A qualified contractor should evaluate and repair or replace as necessary.

10.9.2 – Cabinets & Counters
WORN FINISH
PRIMARY BATHROOM

Wood cabinetry had a finish that was worn or peeling. Recommend a qualified contractor to evaluate and repair or replace as needed.

10.10.1 – Drain Waste and Vent System
NOT WORKING – TUB STOPPER
PRIMARY BATHROOM

The drain stop did not work or did not hold water in the tub.  A qualified contractor should evaluate and repair or replace as necessary.

10.12.1 – Plumbing Fixtures
LOOSE IN WALL – CONTROL VALVE
PRIMARY

A control valve was loose in the wall. This will cause caulking/sealant to deteriorate at an accelerated rate and may allow water to enter the wall. Over time, this could potentially put added stress on the plumbing connections and develop a leak. Recommend a qualified contractor evaluate and repair or replace it as necessary.

10.12.2 – Plumbing Fixtures
LOOSE IN WALL-TUB SPOUT
PRIMARY

The tub spout was loose in the wall. This will cause caulking/sealant to deteriorate at an accelerated rate and may allow water to enter the wall. Over time, this could potentially put added stress on the plumbing connections and develop a leak. Recommend a qualified contractor evaluate and repair or replace it as necessary.

10.13.1 – Toilets
WHISTLE

A very loud whistle was heard when the toilet was flushed. Suggest a qualified contractor repair or replace as necessary

10.14.1 – Tub, Shower Area
CAULK – CORNERS AND FLOOR
PRIMARY BATHROOM

The tub/shower area had deteriorated or missing sealant (caulking or grout) at the corners and/or floor. Sealant is needed at wall corners inside the shower, corners from tub to wall, and along the floor perimeter.  A qualified contractor should evaluate and repair or replace as necessary.

10.15.1 – Fixture Valve Installation And Temperature
WATER NOT HOT
2ND FLOOR

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate that either the mixing valve (safety feature to limit potential scalding) or control cartridge needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

The hot and cold supply was installed correctly and the property’s overall hot water temperature was within an acceptable range.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

 11 – Bathroom 3
11.5.1 – Floors
FLOOR NOT SEALED AT EDGE
2ND FLOOR GUEST BATHROOM

The floor covering was not sealed at the edges and may allow moisture intrusion.  A qualified contractor should evaluate and repair or replace as necessary.

11.9.1 – Cabinets & Counters
WORN FINISH

Wood cabinetry had a finish that was worn or peeling. Recommend a qualified contractor evaluate and repair or replace as needed.

11.10.1 – Drain Waste and Vent System
NOT WORKING – SINK STOPPER
2ND FLOOR GUEST BATHROOM

The drain stop did not work or did not hold water in the sink.  A qualified contractor should evaluate and repair or replace as necessary.

11.12.1 – Plumbing Fixtures
LOOSE IN WALL – SHOWER ARM
2ND FLOOR GUEST BATHROOM

A shower supply arm was loose in the wall.  This will cause caulking/sealant to deteriorate at an accelerated rate and may allow water to enter the wall. Over time, this could potentially put added stress on the plumbing connections and develop a leak. Recommend a qualified contractor evaluate and repair or replace it as necessary.

11.12.2 – Plumbing Fixtures
WHISTLING
2ND FLOOR GUEST BATHROOM

The supply line (behind the wall or at a fixture connection) whistled intermittently when more than one plumbing fixture was operated. Recommend a qualified contractor to evaluate and repair or replace as needed.

Whistling or squealing water pipes generally results from water being forced through a smaller opening than the plumbing components were designed for. This is may be due to: water pressure too high, worn plumbing components, mineral build-up, or other issues that could only be discovered by dismantling the plumbing components.

11.14.1 – Tub, Shower Area
SEALANT – MULTIPLE AREAS
2ND FLOOR BATHROOM

Some caulking and/or grout in the tub & shower area was missing, loose, old, or poorly done.  Recommend a qualified contractor evaluate and re-seal as needed.

 14 – Water Heating Equipment
14.3.1 – Pipe Connections
MISSING FLEX TUBING

The piping to the water heater is missing flex tubing to prevent the piping from breaking in case the concrete floor heaves or settles.

14.12.1 – Operation & Response to Controls
FLAMES

Flames were not entirely burning a blue color. Orange and yellow flames may be an indicator the fuel-air mixture is not right and gas may not be burning as efficiently as possible. Recommend a qualified contractor evaluate to adjust, repair, or replace fuel-burning components as necessary.

14.13.1 – Water Temperature
 

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace it as necessary.

 16 – Heating
16.1.1 – Heating System Information
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

16.3.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

The fresh air supply is recommended by manufacturers for the efficient operation of fuel-burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

16.3.2 – Combustion Air Supply
OBSTRUCTED

The combustion air supply for this appliance was obstructed. A qualified contractor should evaluate and make necessary corrections according to current standards.

The fresh air supply is recommended by manufacturers for the efficient operation of fuel-burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

 17 – Structural Crawlspace
17.7.1 – Ventilation
OBSTRUCTED

A crawlspace vent was obstructed or covered at the time of inspection. This may prevent proper ventilation into the crawlspace. Recommend a qualified contractor to evaluate and repair or replace as needed.

17.8.1 – Electrical in Crawlspace
JUNCTION BOX MISSING COVER PLATE

The splice/Junction box was missing a cover plate. A qualified contractor should evaluate and repair or replace as necessary.

Subtitle Here

Join our Newsletter

Related Posts

Home inspectors examining exterior siding and windows during a residential property inspection
Top 10 Home Inspection Issues in Colorado Homes

Colorado’s diverse climate and varied terrain present unique challenges for…

Home inspector holding a clipboard with a checklist in front of a residential property
A Closer Look Underground: Sewer Line Inspections

Colorado is known for its dramatic mountain views, booming real…

Tags

5/5
Read our reviews