Home Inspection Centerville Dr Colorado Springs CO

Sub Heading - ACF

Highlights

  Inspection Detail Roof 6 Attic, Insulation, and Ventilation 3 Attic, Insulation, and Ventilation 2 1 Exterior 12 Attached Garage 3 Interior, Doors, Windows 16…

Share:

  2 – Roof

2.2.1 – Roof Covering
Roof Covering 1
Roof Covering 2
MINOR DAMAGE/EROSION

The roof covering material had minor damage or erosion in areas. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.4.1 – Flashing
Flashing 1
Flashing 2
KICK-OUT FLASHING MISSING

The wall flashing was missing kick-out/diverter flashing at the time of the inspection.  This condition could allow moisture to penetrate the exterior wall component. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.4.2 – Flashing
Flashing 3
WALL FLASHING IMPROPERLY SEALED

The wall flashing appeared to be inadequately sealed. This condition could allow moisture to penetrate the exterior wall component. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.6.1 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 1
DENTED/DAMAGED

The combustion exhaust flue was dented/damaged at the time of the inspection. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.7.1 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 2
Roof Drainage Systems 3
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration, or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

2.7.2 – Roof Drainage Systems
Roof Drainage Systems 4
Roof Drainage Systems 5
Roof Drainage Systems 6
MISSING GUTTERS

The gutters were missing in areas.  A qualified contractor should evaluate and repair or replace as necessary.

 3 – Attic, Insulation, and Ventilation
3.1.1 – Attic Access
Attic Access 1
DIRTY

The attic access hatch was dirty and had marks, fingerprints, or scuffs on it. A qualified contractor should evaluate and repair or replace as necessary.

3.1.2 – Attic Access
Attic Access 2
HATCH NOT INSULATED

The attic access hatch was not properly insulated. A qualified contractor should evaluate and repair or replace as necessary.

3.7.1 – Exhaust System Vents
Exhaust System Vents 1
LOOSE/DISCONNECTED – VENT DUCT
NEEDS TO BE REPOSITIONED

A vent duct was loose and/or disconnected. This may create moisture/mold issues or a possible fire hazard if not corrected.

A qualified contractor should evaluate and repair or replace as needed.

 4 – Attic, Insulation, and Ventilation 2
4.2.1 – Attic Structural Components
Attic Structural Components 1
ENGINEERED TRUSS SPLIT

One or more engineered truss was split.  A qualified contractor should evaluate and repair or replace as necessary. Axium recommends our premier partner – Level Engineering. They can be contacted at 720-400-8148 or online at www.axiuminspections.com/structural-engineer.

 5 – Exterior
5.2.1 – Driveways
Driveways 1
Driveways 2
HEAVING AND/OR SETTLING

The driveway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose, or it can no longer support the weight causing it to sink or crack. This condition could potentially cause a trip hazard.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
PEELING PAINT

Peeling paint was present in areas.

Recommend a qualified contractor should evaluate and repair or replace as needed.

5.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 2
Wall-Covering, Flashing & Trim 3
SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

5.5.1 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 1
DAMAGE – FASCIA

The fascia was damaged in one or more areas.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.10.1 – Window Wells
Window Wells 1
WINDOW WELLS DEBRIS

Window wells had accumulated soil, leaves, and other debris which should be cleared to encourage proper drainage and minimize the retaining of moisture near the foundation and moisture intrusion and damage through the window area. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

5.11.1 – Walkways
Walkways 1
CRACK AT STEP(S)

Cracking or separation was present at the concrete step(s) in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.11.2 – Walkways
Walkways 2
HEAVING AND/OR SETTLING

The walkway(s) showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose or it can no longer support the weight causing it to sink or crack.

  • This causes cracks in the concrete.
  • This creates trip hazards that could result in injury.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
TREE LIMBS CONTACT ROOF

The tree limbs that are in contact with the roof or hanging near the roof should be trimmed. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

5.13.1 – Sprinkler System Supply Line
Sprinkler System Supply Line 1
IMPROPER REPAIRS, LEAKING

The sprinkler system supply line was leaking at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as needed.

5.14.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
DRIPS AT KNOB

The outside water faucet drips at the knob when turned on. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.18.1 – Exterior Vents
Exterior Vents 1
THE VENT FLAP STUCK OPEN

The dryer vent had a flap that was stuck open. The clothes dryer vent may be clogged which is a potential fire hazard. This may also allow rodents or insects to enter the interior.  Recommend qualified contractors should evaluate and clean, repair, or replace as necessary.

5.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
Roof Drainage - Downspouts & Extensions 2
EXTENSIONS NOT POSITIONED PROPERLY

One or more downspout extensions were not properly positioned. Extensions should be properly attached with a proper slope to guide run-off 5 feet away from the foundation structure.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

 6 – Attached Garage
6.2.1 – Occupant Door
Occupant Door 1
DAMAGED – WEATHER STRIPPING

An entry door in the garage had damaged, missing, or loose weather stripping.

6.2.2 – Occupant Door
Occupant Door 2
NOT SELF CLOSING

The door between the garage and the living space failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazards and toxic fumes. A qualified contractor should evaluate and repair or replace as necessary.

6.4.1 – Floor
Floor 1
CRACKING – COMMON

The concrete floor in the garage was cracked. Due to expansive soils, minor cracks are to be expected in the slabs or control joints. Recommend a qualified contractor to evaluate and repair or replace as needed.

 7 – Interior, Doors, Windows
7.2.1 – Ceilings & Walls
Ceilings & Walls 1
MINOR CRACKS-CEILING

Minor cracking was visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

7.2.2 – Ceilings & Walls
Ceilings & Walls 2
NAIL POPS-WALLS

There were “nail pops” visible on the interior walls.  A qualified contractor should evaluate and repair or replace as necessary.

7.2.3 – Ceilings & Walls
Ceilings & Walls 3
Ceilings & Walls 4
NAIL POPS-CEILINGS

There were “nail pops” visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

7.3.1 – Floors
Floors 1
CARPET STAINS

The carpet was stained in areas. A qualified contractor should evaluate and repair or replace as necessary.

7.3.2 – Floors
Floors 2
CARPET LOSE

The carpet was loose or baggy and may need to be restretched.  A qualified contractor should evaluate and repair or replace as necessary.

7.3.3 – Floors
Floors 3
MISSING/DAMAGED GROUT

The tile floor had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

7.3.4 – Floors
Floors 4
WEAR AND TEAR

The floors showed signs of minor damage and wear, particularly in high-traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

7.4.1 – Doors
Doors 1
RUBS FRAME

An interior door rubs at the door frame when closing. This may mean the door or frame is out of the square or that hinges may not be installed properly.

A qualified contractor should evaluate and repair or replace as necessary.

7.5.1 – Windows
Windows 1
DAMAGED SILL

The window had a sill and/or surround that was damaged. A qualified contractor should evaluate and repair or replace as necessary.

7.5.2 – Windows
Windows 2
SCREENS DAMAGED/MISSING

Some windows had damaged or missing screens.  A qualified contractor should evaluate and repair or replace as necessary.

7.6.1 – Electrical Outlets
Electrical Outlets 1
LOOSE – OUTLET
SOME AREAS

An electrical outlet was loose in the wall. A qualified contractor should evaluate and repair or replace as necessary.

7.7.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
Electrical Fixtures & Switches 2
NOT WORKING – BULB(S)

One or more light bulbs were not working at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as needed.

7.7.2 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 3
FAN NOISY
SQUEAKING

The ceiling fan was noisy when on.  A qualified contractor should evaluate and repair or replace as necessary.

7.9.1 – Smoke & CO Detectors
Smoke & CO Detectors 1
SMOKE DETECTOR OLD

Some of the smoke detectors appeared to be old and beyond their expected life. A qualified person should repair or replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of the date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

7.10.1 – Installed Heat Source
Installed Heat Source 1
LOW HEAT FURNACE

The supply register supplied lower detectable heat temperatures than adjacent heat sources at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

7.11.1 – Fireplaces Gas/LP
Fireplaces Gas/LP 1
GLASS CLOUDY

The glass at the fireplace had a cloudy appearance. A qualified contractor should evaluate and repair or replace as necessary.

 8 – Kitchen
8.3.1 – Ceilings & Walls
Ceilings & Walls 1
SIGNS OF REPAIR-CEILINGS

The ceilings had signs of the previous repair.  A qualified contractor should evaluate and repair or replace as necessary.

8.5.1 – Cabinets & Counters
Cabinets & Counters 1
GROUT – BACKSPLASH

The tile backsplash had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

8.5.2 – Cabinets & Counters
Cabinets & Counters 2
LOOSE – HINGE

The cabinet hinge was loose and not securely fastened.  A qualified contractor should evaluate and repair or replace as necessary.

8.7.1 – Windows
Windows 1
UNABLE TO OPEN BLINDS

Unable to open blinds, Block by sink faucet fixture. Recommend a qualified contractor to evaluate and repair replace as needed.

8.14.1 – Range/Oven/Cooktop
Range/Oven/Cooktop 1
DIRTY, EXCESS GREASE

The oven had excess grease or was dirty at the time of inspection. Excess grease may be a fire hazard. Recommend a qualified contractor to evaluate and clean as needed.

8.14.2 – Range/Oven/Cooktop
Range/Oven/Cooktop 2
SURFACE SCRATCHES, STAINS

Surface scratches or stains We’re present at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as needed.

8.15.1 – Range Hood
Range Hood 1
THE LIGHT DID NOT WORK

The vent hood light was not working at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

8.18.1 – Installed Heat Source
Installed Heat Source 1
NO HEAT FURNACE

The supply register supplied no detectable heat at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom
10.3.1 – Exhaust Fan
Exhaust Fan 1
Exhaust Fan 2
DIRTY

The bathroom exhaust fan was very dirty and possibly clogged.  A qualified contractor should evaluate and repair or replace as necessary.

10.4.1 – Ceilings & Walls
Ceilings & Walls 1
DAMAGED – CEILINGS

The ceilings showed signs of minor damage and wear.  A qualified contractor should evaluate and repair or replace as necessary.

10.6.1 – Windows
Windows 1
WORN SEALS

The window appeared to have a broken seal that has been compromised.  Condensation and/or cloudiness between the two panes of glass were observed.  This will have a negative impact on energy efficiency.  Also, because there is moisture between the panes with no ventilation, mold can eventually develop.  A qualified contractor should evaluate and repair or replace as necessary.

10.8.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
NOT WORKING – BULB

One or more bulbs were not working in the bathroom at the time of inspection.

Recommend a qualified contractor to evaluate and repair or replace as needed.

10.9.1 – Cabinets & Counters
Cabinets & Counters 1
GROUT – BACKSPLASH/WALL

The tile on the wall or backsplash had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

10.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
LEAKING
OVERFLOW

The sink drain pipe was leaking at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

10.12.1 – Plumbing Fixtures
LOOSE-TUB FAUCET

The tub faucet/spout was loose.  A qualified contractor should evaluate and repair or replace as necessary.

10.13.1 – Toilets
Toilets 1
DAMAGE – BOWL

The toilet had damage to the bowl.  A qualified contractor should evaluate and repair or replace as necessary.

10.14.1 – Tub, Shower Area
Tub, Shower Area 1
POSSIBLE MOLD

Evidence of a possible mold-like substance was observed bath or shower area.  We did not inspect, test, or determine if this growth is or is not a health hazard. The underlying cause is moisture. It is recommended to consult a mold inspector or mold remediation specialist to determine if further action is needed. Further analysis by a mold remediation specialist is recommended. Axium recommends our premier partner – Mold Removal Express. They can be contacted at 720-464-1555 or online at www.axiuminspections.com/mold-removal-express.

10.14.2 – Tub, Shower Area
Tub, Shower Area 2
Tub, Shower Area 3
DETERIORATED – CAULKING/GROUT

Caulking in the shower/tub area deteriorated at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as necessary.

 11 – Bathroom 2
11.13.1 – Toilets
Toilets 1
SEAT LOOSE/DAMAGED

The toilet seat was loose or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

 12 – Bathroom 3
12.10.1 – Drain Waste and Vent System
Drain Waste and Vent System1
LEAKING
LEFT SIDE

The sink drain pipe was leaking at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

12.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
LEAK – DIVERTER VALVE

The diverter valve that diverts water from the tub spout to the shower head was leaking while in the shower position. This may be an indication of the valve beginning to fail.

A qualified contractor should evaluate and repair or replace as necessary.

12.14.1 – Tub, Shower Area
Tub, Shower Area 1
DETERIORATED – CAULKING/GROUT

Caulking in the shower/tub area deteriorated at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as necessary.

12.16.1 –  FlowWater Supply Functional
FlowWater Supply Functional 1
PRESSURE DROP

With at least 2 plumbing fixtures running water, there was a noticeable drop in the water flow after the toilet was flushed. A qualified contractor should evaluate and repair or replace as necessary.

 13 – Plumbing
13.3.1 – Water Supply & Distribution Systems
Water Supply & Distribution Systems 1
SADDLE VALVE

A saddle valve was present at the plumbing at the time of inspection. They are prone to leak over time as the rubber seal will eventually deteriorate and they clog up as calcium deposits build up at the small opening. Recommend a qualified contractor evaluate and replace it with a permanent valve as needed.

 14 – Electrical
14.5.1 – Electrical Circuit Breakers
Electrical Circuit Breakers 1
LOCKOUT BRACKETS IN PLACE

Lockout brackets in place On cooktop and range circuits. Recommend a qualified contractor to evaluate and repair or replace as needed. Recommend asking the current sellers for more information.

 15 – Water Heating Equipment
15.3.1 – Pipe Connections
Pipe Connections 1
CORRODED – PIPE FITTINGS

Pipe fittings at the water heating equipment were corroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 16 – Heating
16.1.1 – Heating System Information
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

16.6.1 – Cabinet
Cabinet 1
Cabinet 2
CONDENSATION LEAK

The furnace cabinet interior at the blower chamber had moisture damage from a condensation leak. A qualified contractor should evaluate and repair or replace as necessary.

16.7.1 – Condensate
Condensate 1
SIGNS OF LEAKING

The condensation drain components for the HVAC system were leaking or showed signs of previous leaking. A qualified contractor should evaluate and repair or replace as necessary.

 17 – Cooling
17.1.1 – Cooling System Information
Cooling System Information 1
LABEL WORN OUT

The manufacturing label on the system was worn out and illegible. This is an indication of old age, or prolonged exposure to harsh elements. Recommend a qualified contractor further evaluate and repair or replace.

17.1.2 – Cooling System Information
SERVICING RECOMMENDED

Based on the age of the cooling system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

17.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
DAMAGED INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

17.2.2 – AC Refrigerant Lines
AC Refrigerant Lines 2
GAP AROUND LINE AT WALL

The air-conditioner refrigerant suction line (large, insulated) exterior wall penetration should be sealed to prevent moisture and insect intrusion. A qualified contractor should evaluate and repair/replace as necessary.

17.3.1 – AC Compressor
AC Compressor 1
AC Compressor 2
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings, and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

17.3.2 – AC Compressor
AC Compressor 3
COIL FINS DAMAGED

There was damage to the air-conditioner condenser coil fins. This limits the ability to dissipate heat. Further damage to the coil fins should be avoided in order to maintain cooling system efficiency and avoid problems from overheating of the compressor. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 

Subtitle Here

Join our Newsletter

Related Posts

Home inspectors examining exterior siding and windows during a residential property inspection
Top 10 Home Inspection Issues in Colorado Homes

Colorado’s diverse climate and varied terrain present unique challenges for…

Home inspector holding a clipboard with a checklist in front of a residential property
A Closer Look Underground: Sewer Line Inspections

Colorado is known for its dramatic mountain views, booming real…

Tags

5/5
Read our reviews