Home Inspection E 16th Ave Longmont CO

Sub Heading - ACF

Highlights

Inspection Detail Roof 3 Attic, Insulation, and Ventilation 4 Exterior 16 Attached Garage 3 Interior, Doors, Windows 11 Kitchen 1 Laundry 2 Bathroom 3 Bathroom…

Share:

 2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
Roof Covering 2
Roof Covering 3
DAMAGED/DETERIORATED

The roof covering material was damaged/deteriorated in some areas.  A qualified contractor should evaluate and repair or replace as necessary.

2.4.1 – Flashing
Flashing 1
KICK-OUT FLASHING MISSING

Wall flashing was missing kick-out or diverter flashing, which is needed where a wall extends past a roof edge.  This may allow moisture intrusion of the exterior walls. A qualified contractor should evaluate and repair or replace as necessary.

2.7.1 – Roof Drainage Systems
Roof Drainage Systems 1
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration, or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 3 – Attic, Insulation, and Ventilation
3.1.1 – Attic Access
Attic Access 1
HATCH NOT INSULATED

The attic access hatch was not properly insulated. A qualified contractor should evaluate and repair or replace as necessary.

3.3.1 – Attic Moisture Intrusion
Attic Moisture Intrusion 1
WATER INTRUSION

Signs of previous water penetration or intrusion into the attic. Watermarks or stains were observed. Recommend asking the seller if there are any recent incidents that have been documented or mitigated.

Further evaluation is recommended.

3.4.1 – Insulation in Attic
Insulation in Attic 1
COMPRESSED – INSULATION

The insulation had been walked on or had stored items compressing it, which reduces the R-value.

Recommend a qualified contractor to evaluate and repair or replace as needed.

3.7.1 – Exhaust System Vents
Exhaust System Vents 1
BATHROOM FAN EXHAUSTS INTO ATTIC

The bathroom vent duct terminated in the attic and did not vent to the exterior of the property.

 4 – Exterior
4.2.1 – Driveways
Driveways 1
CRACKING – MINOR

Minor cracking was visible on the driveway in some areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.2 – Driveways
Driveways 2
DROPPED SURFACE/SLAB

The driveway has dropped or settled in areas, causing a steep or uneven step. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.3 – Driveways
Driveways 3
HEAVING AND/OR SETTLING

The driveway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose, or it can no longer support the weight causing it to sink or crack. This condition could potentially cause a trip hazard.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
Wall-Covering, Flashing & Trim 2
LOOSE – SIDING

The exterior wall-covering material was loose in one or more areas.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 3
PEELING PAINT

Peeling paint was present in areas.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 4
Wall-Covering, Flashing & Trim 5
Wall-Covering, Flashing & Trim 6
SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

4.4.4 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 7
Wall-Covering, Flashing & Trim 8
WOOD ROT

The siding and/or trim appeared to be rotted in areas. Recommend a qualified contractor to evaluate and repair or replace as necessary.

4.5.1 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 1
Eaves, Soffits & Fascia 2
GAPS AT INTERSECTIONS

The eaves had gaps at the edges between soffit panels or roof sheathing which allows insects to enter the attic.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.8.1 – Electrical Outlets
LOOSE OUTLET

An exterior electrical outlet was loose in the wall. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.8.2 – Electrical Outlets

Electrical Outlets 1

NOT GROUNDED – OUTLET

One or more electrical outlets were not grounded. A qualified contractor should evaluate and repair or replace as necessary.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
Vegetation, Grading & Drainage 2
INADEQUATE CLEARANCE GRADE

The top of the foundation wall had inadequate clearance from grade. The top of the foundation wall should be a minimum of six inches above the soil. Inadequate clearance may result in moisture intrusion of the structure.

Recommend a qualified contractor should evaluate and repair as necessary according to current standards.

4.14.1 – Exterior Faucets (Hose Bibs)
DRIPS AT KNOB
FRONT

The outside water faucet drips at the knob when turned on. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.19.1 – Decks & Balconies
Decks & Balconies 1
CONTACT WITH GROUND

A wood support post or wood portion of the deck was in direct contact with the ground/dirt. The wood should be pressure treated and ideally be: placed in a metal bracket and/or cement casing, and have clearance from the ground level. Wood in direct contact with dirt will wick up ground moisture and deteriorate at an accelerated rate if routine maintenance is not kept.

Recommend a qualified contractor to evaluate and repair or replace as needed.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
DENTED -DOWNSPOUT

The downspout (s) is dented. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. When moisture is introduced into the foundation it could also cause possible mold growth. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.21.2 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 2
EXTENSIONS NOT POSITIONED PROPERLY

One or more downspout extensions were not properly positioned. Extensions should be properly attached with a proper slope to guide run-off 5 feet away from the foundation structure.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

4.21.3 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 3
MISSING – EXTENSIONS

The downspout (s) are missing the proper 6 ft. extensions. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 5 – Attached Garage
5.5.1 – Vehicle Door
Vehicle Door 1
MISSING – SAFETY RELEASE

The garage door was missing a safety release.

The manual release handle of the garage door should be colored red so that it can be seen easily. The handle should be at a proper height where it’s easily reachable and not so low that it could be in contact with the top of a vehicle.

Recommend a qualified contractor evaluate and replace the safety release as necessary.

5.6.1 – Door Opener
HOLD BUTTON DOWN

The garage door would not close without holding the button down at the time of the inspection. Recommend a qualified contractor to evaluate and repair or replace as needed.

5.7.1 – Electrical Outlets & Fixtures
Electrical Outlets & Fixtures 1
GFCI – NOT ALL PROTECTED

Ground Fault Circuit Interrupter (GFCI) protection was not provided for all the garage electrical outlets. A qualified contractor should evaluate and implement according to current standards.

Although GFCI protection of garage circuits may not have been required at the time in which this property was built, GFCI protection is now required for all 15- and 20-amp receptacles in a garage, including outlets for refrigerators, sprinkler systems, garage door openers, and washing machines – some items may not be protected on purpose due to the potential for them to go unnoticed and cause damage.

 6 – Interior, Doors, Windows
6.2.1 – Ceilings & Walls
Ceilings & Walls 1
MINOR CRACKS-CEILING

Minor cracking was visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

6.2.2 – Ceilings & Walls
Ceilings & Walls 2
TAPE AND BED

The drywall in some areas revealed the tape and nail bed. A qualified contractor should evaluate and repair or replace as necessary.

6.3.1 – Floors
Floors 1
Floors 2
CARPET STAINS

The carpet was stained in areas. A qualified contractor should evaluate and repair or replace as necessary.

6.3.2 – Floors
Floors 3
Floors 4
CARPET LOSE

The carpet was loose or baggy and may need to be restretched.  A qualified contractor should evaluate and repair or replace as necessary.

6.3.3 – Floors
Floors 5
FLOOR SQUEAKS

The floor squeaks when stepped on.  A qualified contractor should evaluate and repair or replace as necessary.

6.4.1 – Doors
SWINGS OPEN/CLOSED
MIDDLE BEDROOM

The door swings open or closed by itself.  A qualified contractor should evaluate and repair or replace as necessary.

6.6.1 – Electrical Outlets

Electrical Outlets 1

Electrical Outlets 2
MISSING – FACEPLATE

An electrical outlet had a missing faceplate. A qualified contractor should evaluate and repair or replace as necessary.

6.7.1 – Electrical Fixtures & Switches
LOOSE – SWITCH

The switch was loose and not properly secured. A qualified contractor should evaluate and repair or replace as necessary.

6.8.1 – Stairways & Railings
LOOSE – HANDRAIL

At the interior stairs, the handrail was loose.  A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

6.9.1 – Smoke & CO Detectors
CO DETECTOR MISSING

Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends the installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009, which requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage.

There are no carbon monoxide detectors on the lower or upper levels.

6.11.1 – Fireplaces Gas/LP
GAS LEAK

The gas-fueled fireplace had an active gas leak detected. The fireplace and components could not be inspected for proper operation. A qualified contractor should evaluate and repair as necessary.

 7 – Kitchen
7.16.1 – Mounted Microwave
NOT WORKING

The microwave was not functioning at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

 8 – Laundry
8.9.1 – Electrical Outlets

Laundry Electrical Outlets 1

GFCI PROTECTION IS NOT PRESENT

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

8.9.2 – Electrical Outlets
OUTLET LOSE
LAUNDRY AREA

An electrical outlet was loose in the wall. A qualified contractor should evaluate and repair or replace as necessary.

 9 – Bathroom
9.2.1 – Doors
NOT LATCHING SECURELY
PRIMARY BATHROOM

An interior door did not latch properly. This may be that it was not shimmed properly at the jamb (too wide) or the strike plate was not in the correct position.

A qualified contractor should evaluate and repair or replace as necessary.

9.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
Drain Waste and Vent System 2
CLOGGED/SLOW – SINK DRAIN
PRIMARY BATHROOM

The sink drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

9.13.1 – Toilets
LOOSE ON THE FLOOR

The toilet was loose on the floor. This condition typically is caused by loose bolts or nuts and/or missing floor seals. The loose toilet can result in leaks, water damage, and mold, as well as damage to the toilet, water supply lines, bolts, and drainage pipes. A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.2.1 – Doors
STRIKE NOT LATCHING
UPSTAIRS BATHROOM

The door would not latch when closed and may need adjustment at the strike plate to latch properly. A qualified contractor should evaluate and repair or replace as necessary.

10.13.1 – Toilets
LOOSE ON THE FLOOR

The toilet was loose on the floor. This condition typically is caused by loose bolts or nuts and/or missing floor seals. The loose toilet can result in leaks, water damage, and mold, as well as damage to the toilet, water supply lines, bolts, and drainage pipes. A qualified contractor should evaluate and repair or replace as necessary.

 11 – Bathroom 3
11.13.1 – Toilets
LOOSE ON THE FLOOR
1/2 BATHROOM

The toilet was loose on the floor. This condition typically is caused by loose bolts or nuts and/or missing floor seals. The loose toilet can result in leaks, water damage, and mold, as well as damage to the toilet, water supply lines, bolts, and drainage pipes. A qualified contractor should evaluate and repair or replace as necessary.

 13 – Electrical
13.2.1 – Distribution Panels
Distribution Panels 1
MISSING – CIRCUIT LABELS

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power to.

Recommend a qualified contractor to verify the breakers and accuracy of any existing labeling as necessary.

 14 – Water Heating Equipment
14.3.1 – Pipe Connections
Pipe Connections 1
MISSING FLEX TUBING

The piping to the water heater is missing flex tubing to prevent the piping from breaking in case the concrete floor heaves or settles.

14.4.1 – Expansion Tank / Valve
Expansion Tank / Valve 1
NOT SECURED

The expansion tank was not properly secured. A qualified contractor should evaluate and repair or replace as necessary.

 15 – Heating
15.7.1 – Condensate
Condensate 1
SIGNS OF LEAKING

The condensation drain components for the HVAC system were leaking or showing signs of the previous leaking. A qualified contractor should evaluate and repair or replace as necessary.

 16 – Cooling
16.1.1 – Cooling System Information
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the cooling system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimated Life Expectancy Chart for Homes

16.1.2 – Cooling System Information
SERVICING RECOMMENDED

Based on the age of the cooling system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

16.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
DAMAGED INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

16.3.1 – AC Compressor
AC Compressor 1
COIL FINS DAMAGED

There was damage to the air-conditioner condenser coil fins. This limits the ability to dissipate heat. Further damage to the coil fins should be avoided in order to maintain cooling system efficiency and avoid problems from overheating of the compressor. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 

16.6.1 – Cooling System Operation
Cooling System Operation 1
Cooling System Operation 2
DID NOT PRODUCE COOLED AIR

The cooling system turned on but did not operate as expected by producing adequately conditioned cooled air. An ambient air test was performed to determine if the difference in temperatures of the supply and return air was between 14 degrees and 22 degrees. A qualified contractor should evaluate and repair/replace as necessary.

16.7.1 – Evaporator Coils
Evaporator Coils 1
GAP IN REFRIGERANT LINES

There was a gap where the refrigerant lines enter the plenum. Recommend a qualified contractor evaluate and seal as needed.

 17 – Structural Basement
17.7.1 – Insulation
Insulation 1
INSULATION DAMAGED

The basement insulation was damaged. A qualified contractor should evaluate and repair or replace as necessary.

Subtitle Here

Join our Newsletter

Related Posts

Home inspectors examining exterior siding and windows during a residential property inspection
Top 10 Home Inspection Issues in Colorado Homes

Colorado’s diverse climate and varied terrain present unique challenges for…

Home inspector holding a clipboard with a checklist in front of a residential property
A Closer Look Underground: Sewer Line Inspections

Colorado is known for its dramatic mountain views, booming real…

Tags

5/5
Read our reviews