Signs of previous water penetration or intrusion into the attic. Watermarks or stains were observed. Recommend asking the seller if there are any recent incidents that have been documented or mitigated.
Further evaluation is recommended.

The insulation had been walked on or had stored items compressing it, which reduces the R-value.
Recommend a qualified contractor to evaluate and repair or replace as needed.

The bathroom vent duct terminated in the attic and did not vent to the exterior of the property.

The property had ceiling materials that may contain asbestos. Ceiling tiles or popcorn textures were manufactured or installed using asbestos as late as the early 90s.
In the past, asbestos fibers were added during production to strengthen and increase durability. Materials that contain asbestos, when intact and in good condition, are generally considered non-friable and not hazardous. Heat, water, weathering, or aging can weaken asbestos materials to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized, or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized, or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.

A transition piece was loose between two sections of flooring. A qualified contractor should evaluate and repair or replace as necessary.


The door had a loose handle or knob. A qualified contractor should evaluate and repair or replace as necessary.

The door would not latch when closed and may need adjustment at the strike plate to latch properly. A qualified contractor should evaluate and repair or replace as necessary.

Carbon monoxide detectors did not operate when tested. The inspector recommends the installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009, which requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage within a specified distance of each room lawfully used for sleeping purposes.

The sliding glass or screen door did not operate properly. The door(s) were operated and did not slide smoothly on the track and/or close using normal operating force.
A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

The glass appeared to have a broken seal that has been compromised. Condensation and/or cloudiness between the two panes of glass were observed. This will have a negative impact on energy efficiency. Also, because there is moisture between the panes with no ventilation, mold can eventually develop. A qualified contractor should evaluate and repair or replace as necessary.

A bulb at an exterior light fixture did not respond to the switch at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

The exterior electrical outlet was missing a weatherproof covering. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

An exterior electrical outlet was not working. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Cracked or split boards were present on the deck. This condition is a structural defect and potential safety hazard.
A qualified contractor should evaluate and repair or replace as necessary.


Loose board(s) were visible on the flooring at the deck.
A qualified contractor should evaluate and repair or replace as necessary.


Improper spacing was noted between balusters, spindles, and rails. This is a safety hazard, especially for small children.
Guards may not allow the passage of a sphere 4 inches in diameter.
Correction and further evaluation are recommended.

The flashing on the downhill side of the skylight is bent with exposed nails. A qualified roofing contractor should investigate and repair or replace as necessary.

The walls showed signs of minor damage and wear. A qualified contractor should evaluate and repair or replace as necessary.

No ground fault circuit interrupter (GFCI) protection was provided for kitchen electrical outlets. Although GFCI protection of kitchen circuits may not have been required at the time in which this property was built, as general knowledge of safe building practices has improved with the passage of time building standards have changed to reflect current understanding. The inspector recommends updating the existing kitchen electrical circuits to provide GFCI protection. This can be achieved by:
1. Replacing the current standard outlets with GFCI outlets.
2. Replacing the first circuit outlet located closest to the main electrical service panel with the GFCI outlet
3. Replacing the breaker currently protecting the electrical circuit that contains these outlets with the GFCI breaker.
A qualified contractor should evaluate and repair or replace as necessary.

A fixture or bulb was not responding to switches at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

The sink drain line had a flex pipe used as part of the drain line. Flexible drain lines can smell, clog, leak or fail. Flex lines design includes multiple folds in which moisture may become trapped and mold may grow. A qualified contractor should evaluate and repair or replace as necessary.
The food waste disposer hums. A qualified contractor should evaluate and repair or replace as necessary.

The food waste disposer was missing the wiring connector (clamp and bushing). A qualified contractor should evaluate and repair or replace as necessary.

The dishwasher drain line came out from a low location and did not discharge into a higher drain pipe. Dishwasher drain lines require a “high loop” in the line in order to drain properly. A “high loop” may have been hidden behind the appliance itself. The high loop in the drain hose is to keep water from settling in the hose to prevent any odors from backing up into the dishwasher. Food or debris may become stuck in the line and smell or mold if not corrected. Recommend a qualified contractor to evaluate and repair or replace as needed.

The vent hood light was not working at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
There was no ventilation (exhaust fan or openable window) In the laundry area. Normally an exhaust fan or an openable window is needed for proper ventilation. A qualified contractor should evaluate and repair or replace as necessary.

A GFCI outlet was not grounded and did not trip when tested. A GFCI requires a ground wire to route electricity when tripped. A qualified contractor should evaluate and repair or replace as necessary.

The countertop needs caulking with silicone along the backsplash. A qualified contractor should evaluate and repair or replace as necessary.

Flexible drain lines can clog, leak, or fail. Flex lines design includes multiple folds in which moisture may become trapped and mold may grow. A qualified contractor should evaluate and repair or replace as necessary.

The bathtub drain stop was damaged, missing, or did not operate properly. A qualified contractor should evaluate and repair or replace as necessary.

A shower supply arm was loose in the wall. This will cause caulking/sealant to deteriorate at an accelerated rate and may allow water to enter the wall. Over time, this could potentially put added stress on the plumbing connections and develop a leak. Recommend a qualified contractor evaluate and repair or replace it as necessary.

The tub/shower area had deteriorated or missing sealant (caulking or grout) at the corners and/or floor. Sealant is needed at wall corners inside the shower, corners from tub to wall, and along the floor perimeter. A qualified contractor should evaluate and repair or replace as necessary.


An electrical outlet was not working. A qualified contractor should evaluate and repair or replace as necessary.

The countertop needs caulking with silicone along the backsplash. A qualified contractor should evaluate and repair or replace as necessary.

The bathtub drain stop was damaged, missing, or did not operate properly. A qualified contractor should evaluate and repair or replace as necessary.


The bathtub finish was chipped or damaged. A qualified contractor should evaluate and repair or replace as necessary.

The tub/shower area had deteriorated or missing sealant (caulking or grout) at the corners and/or floor. Sealant is needed at wall corners inside the shower, corners from tub to wall, and along the floor perimeter. A qualified contractor should evaluate and repair or replace as necessary.

The tub/shower area had deteriorated or missing sealant (caulking or grout) where the shower wall rests on the tub and/or at the inside corners. A qualified contractor should evaluate and repair or replace as necessary.

Evidence of a possible mold-like substance was observed bath or shower area. We did not inspect, test, or determine if this growth is or is not a health hazard. The underlying cause is moisture. It is recommended to consult a mold inspector or mold remediation specialist to determine if further action is needed. Further analysis by a mold remediation specialist is recommended. Axium recommends our premier partner – Mold Removal Express. They can be contacted at 720-464-1555 or online at www.axiuminspections.com/mold-removal-express.

The manufacturing label on the system was worn out and illegible. This is an indication of old age or prolonged exposure to harsh elements. Recommend a qualified contractor further evaluate and repair or replace.

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings, and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.