The roof covering material had minor damage in some areas. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

The drip edge flashing along the rake/eave was missing in areas. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

One or more combustion appliance exhaust flue(s) did not extend far enough above the roof. To ensure proper and safe operation, exhaust flues should extend at least 3 feet above the roof, and 2 feet above any portion of the roof within 10 feet (measured horizontally). A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.
Siding showed cracking and or damage in one or more places. Recommend monitoring, and if the problem exacerbates, a qualified contractor should evaluate and repair or replace as necessary and according to current standards.
Peeling paint was present in areas.
Recommend a qualified contractor should evaluate and repair or replace as needed.
There were signs of previously repaired damage. Recommend inquiring with current homeowners for any further information. Should repairs be significant or failing, we recommend a qualified contractor should evaluate and repair or replace as needed.

The exterior door was damaged or in poor condition. It appears a dog door was once installed and has since been covered with poor quality.
A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

The front door knob interior hardware is damaged. The key gets stuck in the a lot and does not operate properly. A qualified contractor should evaluate and repair or replace as necessary.



Window wells had accumulated dead rodents, soil, leaves, and other debris which should be cleared to encourage proper drainage and minimize the retaining of moisture near the foundation and moisture intrusion and damage through the window area. A qualified contractor should evaluate and repair or replace as necessary according to current standards.


The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation. Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving or settling, depending on soil composition, moisture content and other conditions.The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.
The exterior foundation wall had cracks at the corner. A qualified contractor should evaluate and repair or replace as necessary. Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540.
One or more downspout extensions were not properly positioned. Extensions should be properly attached with a proper slope to guide run-off 5 feet away from the foundation structure.
Recommend a qualified contractor evaluate and repair or replace as necessary.

The inspector was unable to verify that the door was fire rated . This may be considered a fire safety hazard. The door between the garage and the house should be a solid wood door at least 1-3/8 inches thick, a solid or honeycomb-core steel door at least 1-3/8 inches thick, or a 20-minute fire-rated door. This means that should a fire occur in garage, the occupant door does not afford protection until firemen arrive. A qualified contractor should evaluate and repair or replace as necessary.
The door between the garage and the living space failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazard and toxic fumes. A qualified contractor should evaluate and repair or replace as necessary.

An entry door in the garage rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly.
A qualified contractor should evaluate and repair or replace as necessary.

The garage door was hard to lift or the spring(s) did not support the weight of the door when tested.
Recommend a qualified contractor evaluate and repair or replace as necessary.

An extension cord was being used to power the garage door operator. Extension cords are for temporary use only, and the operator should be plugged into a dedicated outlet. Recommend a qualified contractor evaluate and update to current building standards as necessary.

The photo-electric reverse sensors are installed too high from the garage floor surface.
The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

The photo-electric reverse sensors are installed too high from the garage floor surface.
The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

Ground Fault Circuit Interrupter (GFCI) protection was not provided for all the garage electrical outlets. A qualified contractor should evaluate and implement according to current standards.
Although GFCI protection of garage circuits may not have been required at the time in which this property was built, GFCI protection is now required for all 15- and 20-amp receptacles in a garage, including outlets for refrigerators, sprinkler systems, garage door openers, and washing machines – some items may not be protected on purpose due to the potential for them to go unnoticed and cause damage.


The ceiling and/or walls showed various signs of minor defects at numerous locations including all or some of the following: damage, cracks, holes, previous repairs, and/or improper repairs. A representative number of pictures were taken to provide an example. Should any of these issues appear excessive we recommend a qualified contractor should evaluate and repair or replace items as necessary.
The door would not latch when closed, and may need adjustment at the strike plate to latch properly. A qualified contractor should evaluate and repair or replace as necessary.

Some windows had damaged or missing screens. A qualified contractor should evaluate and repair or replace as necessary.



The sealant was damaged, deteriorated or otherwise insufficient around the window. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.
At the interior stairs, the handrail was loose. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

Some of the smoke detectors appeared to be old and beyond their expected life. A qualified person should repair or replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.
The fireplace did not have an accessible shut gas off valve above the floor. A qualified contractor should evaluate and install as necessary.

The glass at the fireplace had a cloudy appearance. A qualified contractor should evaluate and repair or replace as necessary.
The flame for the gas fireplace was weak and could hardly be visible seen. A qualified contractor should evaluate and repair or replace as necessary.


The cabinet door and/or hardware was warped and the door does not stay completely closed. A qualified contractor should evaluate and repair or replace as necessary.
The laundry door lock was installed on the wrong side. A qualified contractor should evaluate and repair or replace as necessary.

The shower door would not close completely at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

An area of the subfloor felt weak or damaged when walked on. A qualified contractor should evaluate and repair or replace as necessary.

The drain stop did not work or did not hold water in the sink. A qualified contractor should evaluate and repair or replace as necessary.
There was a leak at the shower head connection at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.



The water coming from this source is rusty, brown or otherwise discolored. A qualified contractor should evaluate and repair or replace as necessary.
The toilet won’t flush unless the lever is held down briefly. A qualified contractor should evaluate and repair or replace as necessary.
The toilet leaked from the tank into the bowl, causing the toilet to refill repeatedly. This is most likely caused by the flapper valve not sealing the tank completely when closed. A qualified contractor should evaluate and repair or replace as necessary.
The toilet was caulked all-around at the time of inspection. Caulking around a toilet should leave about a one-inch gap in the caulk at the back of the toilet. The gap is to allow water to escape out in the event of a leak, otherwise, a leak may create damage as it’s not able to be discovered as quickly. Recommend a qualified contractor evaluate and repair or replace as needed.

The base cabinet was damaged from moisture intrusion. A qualified contractor should evaluate and repair or replace as necessary.
The tub faucet/spout was loose. A qualified contractor should evaluate and repair or replace as necessary.

There was a leak at the shower head connection at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.

The water coming from this source is rusty, brown or otherwise discolored. A qualified contractor should evaluate and repair or replace as necessary.
The shower diverter did not divert all of the water to the shower and a stream of water passed though bathtub spout when the shower was on. A qualified contractor should evaluate and repair or replace as necessary.

The shower head was not operating properly and needs replaced. Some spouts did not provide water flow. A qualified contractor should evaluate and repair or replace as necessary.
The toilet leaked from the tank into the bowl, causing the toilet to refill repeatedly. This is most likely caused by the flapper valve not sealing the tank completely when closed. A qualified contractor should evaluate and repair or replace as necessary.
An electrical outlet was wired to a light fixture and is not separate. If the outlet is tripped then the light/fan will not work. A qualified contractor should evaluate and repair or replace as necessary.


The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate that either the mixing valve (safety feature to limit potential scalding) or control cartridge needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.
Hot and cold supply was installed correctly and the property’s overall hot water temperature was within an acceptable range.
Recommend a qualified contractor evaluate and repair or replace as necessary.

Wires in the electrical panel overlapped with breakers, additional wires and/or the bus bar. Wires should be limited to one side of the panel without crossing to the other side. This is a safety hazard. A qualified contractor should evaluate and repair or replace as necessary.

The water heater shut off valve was difficult to access at the time of inspection. If it is behind flue pipes it should be noted that the possibility of getting burned by the flue pipe is significant. Recommend a qualified contractor evaluate and repair or replace as necessary.

The piping to the water heater is missing flex tubing to prevent the piping from breakage in case the concrete floor heaves or settles.
The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.
Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.
The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.
Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

The heating system cabinet was corroded, rusted or damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.

The HVAC system air filter was very dirty or clogged. This condition reflects a lack of regular maintenance of the HVAC system. Clogged filters can restrict airflow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the heating and cooling system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing the filter, as well as cleaning, servicing, and evaluating the HVAC system by a qualified HVAC professional and repair or replace as necessary.
The furnace was short-cycling (repeated start-up and shut-down within minutes of each other) at the time of the inspection. Most systems should run about 2-3 cycles per hour. A qualified contractor should evaluate and repair or replace as necessary.