Some of the shingles appear to be de-granulated in areas. Recommend a qualified contractor to evaluate and repair or replace as necessary.


Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.
Debris in gutters can also conceal rust, deterioration, or leaks that are not visible until cleaned.
A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

The gutters were missing in areas. A qualified contractor should evaluate and repair or replace as necessary.

The attic access hatch was dirty and had marks, fingerprints, or scuffs on it. A qualified contractor should evaluate and repair or replace as necessary.


The attic access hatch had insulation that was not secured to the access hatch. A qualified contractor should evaluate and repair or replace as necessary.

The driveway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose, or it can no longer support the weight causing it to sink or crack. This condition could potentially cause a trip hazard.
A qualified contractor should evaluate and repair or replace as necessary and according to current standards.


The exterior of the garage door has one or more damaged panels. A qualified contractor should inspect and repair as necessary and according to current standards.

The siding/trim has lifted nails and needs to be tightened.
Recommend a qualified contractor should evaluate and repair or replace as needed.

Cracking or separation was present at the concrete step(s) in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Signs of repairs were present in the walkway(s) areas. Recommend asking the current homeowner for more information, and if repairs appear to be of poor quality it is recommended to have a qualified contractor evaluate further for any additional repairs necessary.

The outside water faucet drips at the knob when turned on. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

One or more downspout extensions were not properly positioned. Extensions should be properly attached with a proper slope to guide run-off 5 feet away from the foundation structure.
Recommend a qualified contractor to evaluate and repair or replace as necessary.



One or more electrical outlet(s) were wired incorrectly with the hot and neutral wires being reversed. While the outlet still provides power to electronic equipment, a shock hazard has been created as there is still electricity running through the hot wire when the switch is off. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

The dishwasher door rubbed the adjacent wall or cabinet when opening or closing. A qualified contractor should evaluate and repair or replace as necessary.

The convection fan was noisy during the brief testing of the convection bake setting. Recommend a qualified contractor evaluate further and repair or replace as needed.

The floor squeaks. A qualified contractor should evaluate and repair or replace as necessary.

The countertop needs caulking with silicone along the backsplash. A qualified contractor should evaluate and repair or replace as necessary.

An interior door did not latch properly. This may be that it was not shimmed properly at the jamb (too wide) or the strike plate was not in the correct position.
A qualified contractor should evaluate and repair or replace as necessary.

The floor squeaks. A qualified contractor should evaluate and repair or replace as necessary.

The countertop needs caulking with silicone along the backsplash. A qualified contractor should evaluate and repair or replace as necessary.

A shower supply arm was loose in the wall. This will cause caulking/sealant to deteriorate at an accelerated rate and may allow water to enter the wall. Over time, this could potentially put added stress on the plumbing connections and develop a leak. Recommend a qualified contractor evaluate and repair or replace it as necessary.

The water temperature was higher than the acceptable range of 120-130 degrees. We recommend adjusting the water heater thermostat.

The heating system did fire and appeared to be in a serviceable condition at the time of the inspection. However, the interior of the cabinet was dirty. Cleaning, servicing, and/or certification of the HVAC system by a qualified contractor is recommended and repaired or replaced as necessary.

The heating system did fire and appeared to be in a serviceable condition at the time of the inspection. However, the appearance of the flames during operation indicated that gas combustion was not correct. Cleaning, servicing and/or certification of the HVAC system by a qualified contractor is recommended and repaired or replaced as necessary.

The air-conditioner refrigerant suction line (large, insulated) exterior wall penetration should be sealed to prevent moisture and insect intrusion. A qualified contractor should evaluate and repair/replace as necessary.


The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings, and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.